Step 7
SET PRESSURE SWITCH
How to set up manually your pressure switch on the pipe :
1. The contact of the pressure switch is normally closed.
2. Put the pressure switch on the pipe.
3. Remove the cap on the head of the pressure switch.
4. Check that the value is 0 using the instant value connected in bluetooth with the App.
5. Open the irrigation and check if the value is 1.
6. To set it up precisely. During irrigation Screw the screw of the pressure switch until the instant value
go to 0.
7. Then always during the irrigation, unscrew slowly a little bit more the screw in order to get again the 1.
Note: You can also use a multimeter instead of the using the instant value.
FAQ
What are the features required for the Bluetooth® product to work?
Android 4.3 (or more) Smartphones or tablets equipped with Bluetooth Smart 4.0 (or more). iOS 9.0 Apple
iPhone or iPad running (or more) with Bluetooth Smart 4.0 (or more)
How does the rain sensor work?
When connected to the wire the rain sensor acts on the stations. If it is raining, stations won't start; you must
wait for the probe to dry before the programming star again. The manual control is not affected by the rain
sensor conditions.
How can I restart the pairing or the pairing procedure?
To start the pairing procedure again, just bypass the 2 battery connector pins (battery removed) for 30s
minimum
If my device has no more battery, do I lose my programming?
No, they are not lost, it is automatically saved.