Toro TEMPUS-AG-MV User Manual page 6

Main valve or pump controller 1 station

Advertisement

Toro TEMPUS-AG-MV
Step 4
SOLENOID VALVE / PUMP WIRING
1. Plug the TEMPUS-AG-MV as shown below. Use 9V solenoid valves only for a main valve and a relay for a
pump use.
+S- C P 1
Jumper wire
Step 5
CHOICE AND SENSOR SETUP
Warning, by default there are no sensor configured.
The TEMPUS-AG-MV has a + S - sensor input on which you can connect a rain sensor or a flow meter/water
meter or pressure switch after cutting the blue wire. Once the sensor is connected, it is necessary to configure
it in the application.
1. Using the MyToroTempus mobile app, connect to your TEMPUS-AG-MV via Bluetooth.
2. Click on Add Sensor.
3. Select your sensor type and follow the instructions given by the application.
Rain sensor
Jumper wire
Rain sensor
+S- C P 1
Jumper wire
Water meter
6
Vanne 1
Valve 1
Valve common wire
+S- C P 1
Valve 1
Vanne 1
Valve common wire
Valve 1
Vanne 1
Valve common wire
Pressure switch (AON = All or Nothing)
Jumper wire
Pressure switch
Water meter
Connect your + S - input to a water meter equipped with
a flow sensor as shown above. Use dry contact flow
sensors or equivalent. For polarized flow sensors, when
wiring,observe the polarization :
Red wire -> + Black wire - > -
+S- C P 1
+S- C P 1
Vanne 1
Valve 1
Valve common wire