Final Assembly System Test CON'T
2)
Plug the IEC Power Cable into a power source and BB01.
Verify that the front panel LEDs show normal power up message,
"DEQ830" on the left side..
After this message "DIAG: <version>" should display on the left
side.
number for the ME4.
Problems with this inspection indicates that the unit has not
entered Factory Test Mode.
and 2.
Problems with the correct version number indicate that the DUT
has the incorrect software in it, and that it should be updated
to the most recent software.
Problems with this inspection indicates that the unit has been
incorrectly assembled.
been properly plugged in.
DUT has FAILED.
3)
When in Factory Test Mode, pressing PROGRAM will go to next test.
Press PROGRAM.
Verify that the front panel LEDs shows first test message
"EEPROM" for 1 second.
Verify that the front panel LEDs shows first test message
"E
EPROM PASS".
Problems with this inspection indicates that the unit is having
trouble recognizing the PROGRAM button, or that the EEPROM has
failed.
Failure of this test indicates that this sub-assembly cannot
continue further testing.
4)
Press PROGRAM.
Verify that the front panel LEDs shows "COL" for 1 second.
Verify that the front panel LEDs shows first column.
Verify that all the LEDs are on, that they have a consistent
brightness and that they are not flickering.
Problems with this inspection indicates that the unit is
problems with its LED display, and that the DUT has FAILED.
Failure of this test indicates that this sub-assembly cannot
continue further testing.
Verify that the version is the correct, shipping version
Double check that the IEC cable has
This goes to the COL test.
Unplug the unit and repeat steps 1
If this is not the problem, then the