1a) Diagnostic Menus
When entering diagnostic mode, pressing PROGRAM will advance to the next
test.
The test order is as follows:
DIAG -> EEPROM -> COL -> ROW -> ALL -> MIDI -> A. ->
DIG A. ->RESET -> DONE
DIAG
Message
Informs user "Prepare for tests.".
EEPROM
Eeprom Test
When entering EEPROM test, EEPROM test is run automatically. Unit displays
EEPROM FAIL or EEPROM PASS.
COL
LED Test
Turning the VALUE encoder clockwise rotates through LED columns.
ROW
LED Test
Turning the VALUE encoder clockwise rotates through LED rows.
ALL
LED Test
When entering ALL test, unit turns all LEDs on.
MIDI
MIDI Test
When entering MIDI test, MIDI test is run automatically.
MIDI FAIL or MIDI PASS.
A.
Audio Fidelity Test
When entering AUDIO test, unit configures dsp for bypass to run audio
tests. This uses an abbreviated title, "A," to reduce noise caused by the
led matrix scanning.
DIG A.
Digital Audio Test
When entering DIG AUDIO test, digital audio test is run automatically.
Unit displays DIG PASS or DIG FAIL.
to
PASS.
RESET
EEPROM Reset
Allows user to reset EEPROM.
0 to 99 in the 7 segment display, and is finished when the display reaches
"99".
DONE
Message
Informs user "Done with tests.".
Requires MIDI loopback cable to PASS.
Requires ADAT Optical loopback cable
Push encoder to RESET eeprom.
Unit displays
Unit displays