Ceiling Panel
MODEL: RBC-U31PG (W)-E, U31PG (WS)-E
RBC-U31PGS (W)-E, U31PGS (WS)-E
• The product and this manual are provided with important safety notices to ensure safe use and protect the user and
other people from hazards and preclude damage to property.
Be sure that you fully understand the following contents (expressions and graphic symbols) and read this manual
carefully. Always observe the precautions.
• Ask an authorized dealer or qualified installation professional to install the ceiling panel.
Inappropriate installation may result in water leakage, electric shock or fire if you install it by yourself.
• Carry out an installation work securely according to this Installation Manual.
Inappropriate installation may result in water leakage, electric shock or fire.
• Attach the ceiling panel on a ceiling that withstands the weight of the ceiling panel.
Insufficient strength may cause a fall of the unit, which may result in injury.
• Electrical work must be performed by a qualified electrician in accordance with the Installation Manual. Make
sure the air conditioner uses an exclusive power supply.
The capacity shortage of the power circuit or improper electrical work may result in electric shock or fire.
• Connect the specified wires firmly and clamp them securely so that external force applied to the wires does
not affect the connector pins.
Improper wire connection or clamping may result in fire or malfunction.
• Be sure to connect earth wire. (grounding work)
Do not connect the earth line to a gas pipe, water pipe, lightning conductor, or a telephone earth line.
Incomplete earthing may result in electric shock.
• Never modify or repair the product.
Incomplete modification or repair may result in electric shock or fire.
• Wear heavy work gloves during the installation work to avoid injury.
Part name
Quantity
Shape
INSTALLATION MANUAL
Precautions for Safety
WARNING
Components
Ceiling panel
1
Louver
This manual
CAUTION
Installation manual
1
– 1 –
REQUIREMENT
Do not apply excessive force to
the louver, as it may cause a
malfunction.
EN
1-EN

Advertisement

loading

Summary of Contents for Toshiba RBC-U31PG W-E

  • Page 1 INSTALLATION MANUAL Ceiling Panel MODEL: RBC-U31PG (W)-E, U31PG (WS)-E RBC-U31PGS (W)-E, U31PGS (WS)-E Precautions for Safety • The product and this manual are provided with important safety notices to ensure safe use and protect the user and other people from hazards and preclude damage to property. Be sure that you fully understand the following contents (expressions and graphic symbols) and read this manual carefully.
  • Page 2 1. Preparation for Attaching Ceiling Panel Checking Indoor Unit Position This clearance must be 12 to 17. 1. Check the position of the indoor unit using the Installation A clearance outside this range may cause malfunction. Manual. 2. Check whether the ceiling opening size falls within a range of 860 ×...
  • Page 3 Attaching Ceiling Panel (Fig. 1) Drain pipe Rectangular holes of Do not apply excessive force to the louver when attaching indoor unit Electric parts box the ceiling panel, as it may cause malfunction of the louver. 1. Insert the two movable hooks at the inside of the ceiling panel into the rectangular holes of the indoor unit, and hook Refrigerant pipe them tentatively onto the indoor unit.
  • Page 4 Attaching Adjust Corner Caps and Air Brand name indication given at factory shipping Adjust corner cap Inlet Grille * Can be attached at any location. • According to customer requirements, the grille orientation Refrigerant Indoor unit electric parts box of the air inlet grille and the location of the company name pipe side indication on the adjust corner cap can be changed as Wireless Remote Controller Kit...

This manual is also suitable for:

Rbc-u31pg ws-eRbc-u31pgs w-eRbc-u31pgs ws-eRbc-u31pg eRbc-u31pgs e