Slant/Fin VICTORY VSPH/NDV-60 Installation And Operating Instructions Manual page 7

Gas-fired cast-iron boilers for natural and l.p. propane gases
Table of Contents

Advertisement

V
ICTORY VSPH Models
VSPH/NDV-60
VSPH/NDV-90
VSPH/NDV-120
VSPH/NDV-150
VSPH/NDV-180
VSPH/NDV-60
VSPH/NDV-90
VSPH/NDV-120
VSPH/NDV-150
VSPH/NDV-180
VSPH/NDV-60
VSPH/NDV-90
VSPH/NDV-120
VSPH/NDV-150
VSPH/NDV-180
Maximum allowed flue pipe equivalent length (Feet)
Heat-Fab Saf-T vent system (Including EZ Seal)
0 - 5,000 Ft.
Boiler Model
Elevation
Number
Maximum allowed flue pipe equivalent length (Feet)
Z-Flex Z-Vent and Flex-L StaR-34 vent systems
0 - 5,000 Ft.
Boiler Model
Elevation
Number
Maximum allowed flue pipe equivalent length (Feet)
ProTech FasNSeal vent systems
0 - 5,000 Ft.
Boiler Model
Elevation
Number
for
5,000 - 7,500 Ft.
Elevation
40
40
40
40
40
35
35
30
33
28
for
5,000 - 7,500 Ft.
Elevation
35
35
35
35
35
30
30
25
28
23
for
5,000 - 7,500 Ft.
Elevation
30
30
30
30
30
25
25
20
23
18
7,500 - 10,000 Ft.
Elevation
40
35
30
25
23
7,500 - 10,000 Ft.
Elevation
35
30
25
20
18
7,500 - 10,000 Ft.
Elevation
30
25
20
15
15
7