IMPORTANT SAFETY INSTRUCTIONS

WARNING
instructions can cause severe injury and/or death.
WARNING
Suction in suction outlets and/or suction outlet covers which are, damaged, broken, cracked, missing, or unsecured can cause severe injury
and/or death due to the following entrapment hazards:
Hair Entrapment- Hair can become entangled in suction outlet cover.
Limb Entrapment- A limb inserted into an opening of a suction outlet sump or suction outlet cover that is damaged, broken, cracked,
missing, or not securely attached can result in a mechanical bind or swelling of the limb.
Body Suction Entrapment- A negative pressure applied to a large portion of the body or limbs can result in an entrapment.
Evisceration/ Disembowelment - A negative pressure applied directly to the intestines through an unprotected suction outlet sump or
suction outlet cover which is, damaged, broken, cracked, missing, or unsecured can result in evisceration/ disembowelment.
Mechanical Entrapment- There is potential for jewelry, hair decorations, finger, toe or knuckle to be caught in an opening of a suction
outlet cover resulting in mechanical entrapment.
WARNING
o
When outlets are small enough to be blocked by a person, a minimum of two functioning suction outlets per pump must be
installed. Suction outlets in the same plane (i.e. floor or wall), must be installed a minimum of three feet (3') [1 meter] apart, as
measured from near point to near point.
o
Dual suction fittings shall be placed in such locations and distances to avoid "dual blockage" by a user.
o
Dual suction fittings shall not be located on seating areas or on the backrest for such seating areas.
o
The maximum system flow rate shall not exceed the flow rating of as listed on Table 1.
o
Never use system if any suction outlet component is damaged, broken, cracked, missing, or not securely attached.
o
Replace damaged, broken, cracked, missing, or not securely attached suction outlet components immediately.
o
In addition two or more suction outlets per pump installed in accordance with latest ASME, APSP Standards and CPSC
guidelines, follow all National, State, and Local codes applicable.
o
Installation of a vacuum release or vent system, which relieves entrapping suction, is recommended.
WARNING
suction outlets can result in an increase potential for suction entrapment as described above.
WARNING
other material can result in an increase potential for suction entrapment as described above.
WARNING
replaced at least every ten years or if found to be damaged, broken, cracked, missing, or not securely attached.
CAUTION
their being used as means of access to the system by unauthorized or unqualified individuals.
WARNING
WARNING
WARNING
and after pump shut off. Stand clear of circulation system equipment during pump start up. Failure to follow safety and operation
instructions could result in violent separation of the pump housing and cover, and/or filter housing and clamp due to pressure in the system,
which could cause property damage, severe personal injury, or death. Before servicing circulation system, all system and pump controls
must be in off position and filter manual air relief valve must be in open position. Before starting system pump, all system valves must be
set in a position to allow system water to return back to the system. Do not change filter control valve position while system pump is
running. Before starting system pump, fully open filter manual air relief valve. Do not close filter manual air relief valve until a steady
stream of water (not air or air and water) is discharged.
WARNING
pump and/or filter components. Strainer cover must be properly secured to pump housing with strainer cover lock ring. Before servicing
circulation system, filters manual air relief valve must be in open position. Do not operate circulation system if a system component is not
assembled properly, damaged, or missing. Do not operate circulation system unless filter manual air relief valve body is in locked position
in filter upper body.
WARNING
and the National Electric Code (NEC). Hazardous voltage can shock, burn, and cause death or serious property damage. To reduce the
risk of electric shock, do NOT use an extension cord to connect unit to electric supply. Provide a properly located electrical receptacle.
Before working on any electrical equipment, turn off power supply to the equipment.
Hayward Flow Control
- Read and follow all instructions in this IOM manual and on the equipment. Failure to follow
– Suction Entrapment Hazard.
- To Reduce the risk of Entrapment Hazards:
– Failure to remove pressure test plugs and/or plugs used in winterization of the system from the
– Failure to keep suction outlet components clear of debris, such as leaves, dirt, hair, paper and
– Suction outlet components have a finite life, the cover/grate should be inspected frequently and
– Components such as the filtration system, pumps and heater must be positioned so as to prevent
– Never operate or test the circulation system at more than 50 PSI.
– Never change the filter control valve position while the pump is running.
– Hazardous Pressure.
Circulation systems operate under hazardous pressure during start up, normal operation,
– Separation Hazard.
Failure to follow safety and operation instructions could result in violent separation of
– Risk of Electric Shock. All electrical wiring MUST be in conformance with applicable local codes, regulations,
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
www.haywardflowcontrol.com
1-888-HAY-INDL (1-888-429-4635)
ISHCP3000FC Rev A 11/30/16