Nominal Data; Technical Description; Mounting Data; Transport And Storage Conditions - ebm-papst W2S130-BM15-01 Operating Instructions Manual

Hide thumbs Also See for W2S130-BM15-01:
Table of Contents

Advertisement

W2S130-BM15-01

3.2 Nominal data

Motor
M2S052-CA
Phase
1~
Nominal voltage / VAC
115
Frequency / Hz
50
Method of obtaining
fa
data
Valid for approval/
CE
standard
-1
Speed (rpm) / min
2700
Power consumption / W
47
Current draw / A
0.63
Min. ambient
-25
temperature / °C
Max. ambient
50
temperature / °C
Starting current / A
0.98
ml = Max. load · me = Max. efficiency · fa = Free air
cs = Customer specification · ce = Customer equipment
Subject to change

3.3 Technical description

Weight
1.1 kg
Fan size
130 mm
Rotor surface
Painted black
Blade material
Sheet steel, painted black
Housing material
Die-cast aluminum, painted black
Number of blades
5
Airflow direction
"A"
Direction of rotation
Counterclockwise, viewed toward rotor
Degree of protection
IP20
Insulation class
"B"
Installation position
Any
Condensation
None, open rotor
drainage holes
Mode
S1
Motor bearing
Ball bearing
Touch current
< 0.75 mA
according to IEC
60990 (measuring
circuit Fig. 4, TN
system)
Motor protection
Thermal overload protector (TOP)
internally connected
Protection class
I (if protective earth is connected by
customer to the housing's connection point)
Conformity with
EN 60335-1; CE
standards
Approval
CSA C22.2 No. 113; EAC; UL 507; VDE
With regard to cyclic speed loads, note that the rotating parts of
the device are designed for a maximum of one million load
cycles. If you have special questions, consult ebm-papst for
support.
Item no. 11063-5-9970 · ENU · Change 83344 · Approved 2016-05-23 · Page 5 / 9
ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com
Operating instructions

3.4 Mounting data

For screw clearance, see Chapter 3.1 Product drawing
; Secure the screws against unintentional loosening (e.g. use self-
1~
115
Strength class of
60
screws
fa
Any further mounting data required can be taken from the product drawing.
CE

3.5 Transport and storage conditions

; Use the device in accordance with its degree of protection.
3050
46
Max. permitted
ambient temp. for
0.55
motor (transport/
-25
storage)
Min. permitted
70
ambient temp. for
motor (transport/
0.83
storage)

4. CONNECTION AND STARTUP

4.1 Mechanical connection

; Check the device for transport damage. Damaged devices are not to
; Install the undamaged device in accordance with your application.

4.2 Electrical connection

locking screws).
8.8
+ 80 °C
- 40 °C
CAUTION
Cutting and crushing hazard when removing device
from packaging
Blades can bend
→ Carefully remove the device from its packaging, by the fan
housing. Strictly avoid shocks.
→ Wear safety shoes and cut-resistant safety gloves.
be installed.
CAUTION
Possible damage to the device
If the device slips during installation, serious damage can result.
→ Ensure that the device is securely positioned at its place of
installation until all fastening screws have been tightened.
DANGER
Voltage on the device
Electric shock
→ Always connect a protective earth first.
→ Check the protective earth.
DANGER
Faulty insulation
Risk of fatal injury from electric shock
→ Use only cables that meet the specified installation
regulations for voltage, current, insulation material, capacity,
etc.
→ Route cables so that they cannot be touched by any
rotating parts.

Advertisement