Reassembly
Install Oil Sentry
(if equipped)
1. Apply pipe sealant with Teflon
Thread Sealant or equivalent) to threads of Oil
Sentry
switch and install it into breather cover.
Torque to 4.5 N·m (40 in. lb.).
2. Connect wire lead (green) to Oil Sentry
Install Control Panel
1. Assemble choke lever to control bracket.
2. Install control panel to blower housing.
3. Assemble throttle control shaft to control bracket.
Secure throttle shaft bracket with screws to cylinder
head.
4. Connect choke control cable and throttle control
cable to control bracket.
Reconnect Rectifier-Regulator
1. Install rectifier-regulator in blower housing if removed
previously, then connect rectifier-regulator ground
lead with washer and green screw through eyelet. If
a grounding bracket is used, secure with mounting
screw and washer, against outer side of rectifier-
regulator.
2. Install B+ terminal/lead into center position of
rectifier-regulator plug and connect plug to rectifier-
regulator.
62
(Loctite
PST
592™
®
®
®
terminal.
KohlerEngines.com
Install Valve Covers
Torque Sequence
1
4
1. Make sure sealing surfaces are clean.
2. Make sure there are no nicks or burrs on sealing
surfaces.
3. Install a new O-ring in groove of each cover.
4. Position covers on cylinder heads. Locate cover with
oil separator hole on cylinder 1. Install four screws in
each cover and finger tighten.
5. Torque valve cover fasteners to 6.2 N·m (55 in. lb.)
using sequence shown.
6. Install rubber grommet into cylinder 1 valve cover.
Install oil separator into grommet and secure to
blower housing with mounting screws.
3
2
24 690 37 Rev. B