1 Preparing for installation ······························································· 1-1
Safety recommendations ·········································································································· 1-1
Site preparation ······················································································································ 1-1
Installation accessories ············································································································ 1-1
Installation tools ······················································································································ 1-2
2 Installing the AP ········································································· 2-1
Installation flowchart ················································································································ 2-1
Pre-installation tasks················································································································ 2-1
Determining the installation position ···························································································· 2-1
Mounting the AP ····················································································································· 2-2
Mounting the AP on a wall ·································································································· 2-2
Mounting the AP on a ceiling ······························································································ 2-4
Connecting the AP to a power source ·························································································· 2-5
Connecting a PoE power source ·························································································· 2-5
Connecting a local power source ························································································· 2-6
Check after power-on ········································································································ 2-6
Connecting the AP to the network ······························································································· 2-6
3 Appendix A Technical specifications ··············································· 3-1
4 Appendix B Ports and LEDs ·························································· 4-1
Ports ···································································································································· 4-1
LEDs ···································································································································· 4-2
i
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Advertisement

Table of Contents
loading

Summary of Contents for H3C WA6330

  • Page 1: Table Of Contents

    Contents 1 Preparing for installation ······························································· 1-1   Safety recommendations ·········································································································· 1-1   Site preparation ······················································································································ 1-1   Installation accessories ············································································································ 1-1   Installation tools ······················································································································ 1-2   2 Installing the AP ········································································· 2-1   Installation flowchart ················································································································ 2-1   Pre-installation tasks················································································································...
  • Page 2: Preparing For Installation

    Preparing for installation Safety recommendations WARNING! Only qualified personnel can install and remove the AP and its accessories. You must read all safety instructions carefully before working with the AP. To avoid possible bodily injury and equipment damage, read the following safety recommendations before installing the AP.
  • Page 3: Installation Tools

    Installation tools When installing the AP, you might need the following tools. Prepare the installation tools yourself as required. Figure1-2 Installation tools...
  • Page 4: Installing The Ap

    Installing the AP Installation flowchart Figure2-1 Installation flowchart Start Complete pre-installation tasks Determine the mounting option On the wall On the ceiling Install the AP Connect the AP to the power source Connect the AP to the network Pre-installation tasks Before installing the AP, perform the following tasks: •...
  • Page 5: Mounting The Ap

    • The place is not water seeping, water soaking, and condensing. Mounting the AP The AP can be installed only indoors. You can mount the AP on a wall or a ceiling. Mounting the AP on a wall Place the mounting bracket against the wall and mark the installation holes on the wall. Figure2-2 Marking the installation holes on the wall Drill holes with a diameter of 6 mm (0.24 in) and a depth of 30 mm (1.18 in) at the marked locations, as shown in Figure2-3.
  • Page 6 Figure2-4 Hammering the screw anchor into the wall Insert the screws through the installation holes in the wall bracket into the holes in the wall. Fasten the screws to secure the mounting bracket to the wall. Figure2-5 Attaching the mounting bracket to the wall Position the four pegs on the AP into the keyhole slots in the mounting bracket and then slide the AP down until it clicks into place, as shown in Figure2-6.
  • Page 7: Mounting The Ap On A Ceiling

    Mounting the AP on a ceiling CAUTION: The ceiling for installing the AP must be less than 18 mm (0.71 in) in thickness, and can bear a load of 5 kg (11.02 lb). If you must install the AP on a ceiling not strong enough, use boards to reinforce the ceiling.
  • Page 8: Connecting The Ap To A Power Source

    Figure2-9 Attaching the AP to the mounting bracket Verify that the AP is securely installed to prevent it from falling off. Connecting the AP to a power source IMPORTANT: The cable cover is not required in the following conditions: • Shielded network cables are used to connect Ethernet ports on the AP. •...
  • Page 9: Connecting A Local Power Source

    Connecting a local power source You can use an AC/DC power adapter to connect the AP to a local power source. No power adapter is provided with the AP. Prepare one yourself as required. Table2-1 describes the power adapter specifications. Table2-1 Power adapter specifications Item Specification...
  • Page 10 AP name APID State Model Serial ID WA6330 219801A23V8192E00021...
  • Page 11: Appendix A Technical Specifications

    Appendix A Technical specifications Table3-1 Technical specifications Item Specification Dimensions (H × W × D) (without the 45 × 215 × 215 mm (1.77 × 8.46 × 8.46 in) mounting bracket) Weight 940 g (33.16 oz) • 2.4 G: gain of 3 dBi Antenna (built-in) •...
  • Page 12: Appendix B Ports And Leds

    Appendix B Ports and LEDs Ports The AP provides the following ports: • One console port • One USB port • One GE port • One 2.5GE port • One power port The AP also has a reset button and a security slot. The security slot is 7 × 3 mm (0.28 × 0.12 in) in size.
  • Page 13: Leds

    Standards and Port Description protocols Used for connecting the AP to an uplink device for • IEEE802.3 Internet or MAN access. It can also receive PoE+ • power from the uplink device. IEEE802.3u 100/1000/2500M Ethernet copper port (2.5GE/PoE+) • IEEE802.3af It is represented by interface number SGE1/0/1 in the MAP file and smartrate-ethernet 1 for •...