Audio Dubbing - Canon DM-MV300E Manual

Table of Contents

Advertisement

DM-MV300E/MV300iE/MV310E
CHAPTER 1. GENERAL DESCRIPTION OF PRODUCT

7-10 Audio dubbing

1.
Tapes for Audio dubbing
Audio dubbing is possible only on tapes recorded in the 12 bit/SP mode other than the 4 channel sync recording. With all other tapes
the unit stops. It stops when it detects LP mode, 16 bit mode, 4 channel sync type recording, or no recording (warning indication
appears).
2.
Audio dubbing signal input source selection
If an external microphone is connected, the input signal comes via the external microphone, if not connected, the input signal will
come from the built-in microphone.
3.
Audio dubbing operation
1 In the VCR mode, playback-pause the tape at a point from where audio dubbing is to begin, then press the audio dubbing button on
the remote controller.
The unit enters the audio dubbing mode (audio dubbing pause), and the ( ) symbol (audio dubbing) is being indicated on the LCD
panel (CVF).
2 Press the Pause [ ] button turn on sound of the microphone etc.
Audio dubbing starts.
3 Press the Stop [I] button where you want to stop.
The audio dubbing mode is being canceled, the audio dubbing symbol disappears from the display, and the unit stops.
By pressing the Pause [ ] button instead of the Stop [I] button, the audio dubbing mode is not canceled, but instead returns to step
1 (audio dubbing pause).
Another way to cancel the audio dubbing mode is to press the audio dubbing button on while in the audio dubbing pause mode.
In order to set in advance the audio dubbing mode to stop at a certain point of the tape, press the Zero Set Memory button on the
remote controller at the desired point, then after having performed operation in step 2 the unit will automatically stop when it
reaches the point, and the audio dubbing mode will be canceled.
*
Audio input source signal coming from the DV terminal cannot be after-recorded. When the audio dubbing mode is set, no signal
is output from the DV terminal. The sound monitored is the input sound only. Playback sound cannot be monitored.
*
CGMS
The unit does not switch to the audio dubbing mode on a copy-restricted portion of a copy-restricted tape.
The unit stop when it enters a copy-restricted portion following a copy-allowed portion.
1-32