Active infrared “hands-free” switch

Advertisement

Switch 3 – LED On/LED Off
This switch disables the LED,
should this feature be desired.
Factory setting is ON.
Once the Dip switches have been
set, and the unit is installed in the
frame or enclosure, apply power to
the unit and observe operation.
Set both potentiometers to
minimum setting initially (fully
counter-clockwise).
See Diagram 3 for location.
Adjust the range potentiometer
by turning the pot in a clockwise
manner, and passing your hand
in front of the unit. Rotate the pot
until the desired range is obtained.
See Diagram 4 for patterns.
Next, adjust the time delay
potentiometer by turning clockwise
until the desired time delay is
obtained. It is sometimes beneficial
to leave this adjustment set to minimum and utilize the
time delay on the door operator, if present.
NOTE: Timer is non-functional in Toggle Mode.
Install the faceplate using the screws provided.
Do not overtighten!!
OPTIONAL – Apply the included Wheelchair logo to the
frame or wall at desired location. See Diagram 5 on page 4.
Do not apply directly to the faceplate!!
If using this product with an Automatic Door, proceed to
Section 4 for System Inspection Instructions.
Section 4:
System Inspection Instructions
After the Installation and operational check of the system:
1. Place warning label on the door (as per ANSI A156.10
or A156.19 guidelines). This will advise the person
entering the swing side zone that the door will move.
2. Instruct the owner on door system operation and how
to test it. This should be checked on a daily basis.
3. Instruct the owner on what to do if the door or any of
its components become damaged.
4. Strongly recommend to the owner that the complete
entry be inspected twice a year as part of the service
agreement.
CM-324 Active Infrared "Hands-Free" Switch Installation Instructions
Door
CM-324/N3
Frame
1 "
25mm
Diagram 4
Wheelchair
Sticker
Placement
Page 3 to 4
Section 5: Technical Data
Model
CM-324
Body Size
4" L x 1" W x 1 ½" Deep
Mounting
2 x #6-32 MS
Faceplates Sizes
Jamb, 1-gang, & 2-gang
Technology
Infra-Red with Coded Modulated Carrier
Security
Automatic Self-changing ID
Operating Modes
Pulse (sense) / Toggle
Operating Temp
-4 to +153 ºF (-20 to +85 ºC)
Operating Voltage
12-24 Volts, AC/DC ± 12%
Current Draw
50 - 60 mA.
Response Time
100 ms.
Activation Range:
Minimum
1" – 3"
Maximum
1" – 26"
Relay Output
Form C (SPDT)
Relay Contact Rating
5 amps @ 30 VDC
Output Type
Normal or Fail-Safe
Connections
11" 22 AWG Leads
Time Delay
1 to 5 Seconds
Electrical Life
100,000 Operations@ Rated Capacity
500,000 Operations@ ½ Rated Capacity
Section 6: Warranty
Camden Door Controls guarantees the Sure-Wave™ to
be free from manufacturing defects for 3 years from date
of sale.
If during the first 3 years the CM-324 fails to perform
correctly, it may be returned to our factory where it will be
repaired or replaced (at our discretion) without charge.
Except as stated herein, Camden extends no warranties
expressed or implied regarding function, performance or
service.
Questions? Call us toll-free at 1-877-226-3369