Smoke Detector
R
LX928-D
Product size
φ100.4mm
Summary
The product is a new type of photoelectric smoke
detector, When it detects smoke, it will output signal
immediately and trigger connected unit to work, which
tell you in advance that fire will occurs and avoid
unwanted loss, and take you safety and convenience.
Specifications
Power source: DC12V~DC33V
Static current:<60uA
Alarm current: ≤30mA
Working temperature:-10°C~40°C
Working humidity: 10%-95%RH non-condensing
Double indicator.
Where fit to install smoke detector
1. First, you need to install at least one item in each
bedroom and route.
2. When a fire breaks out, the stairs are important for
you to rush out, so you must install a smoke detector
on top of the stairs.
45.5mm
3. At least one smoke detector is required for each
26.8mm
space on each floor, including the finished attic and
basement.
4. Install a detector next to each electrical facility.
You'd better install a smoke detector in the middle of
the ceiling because the smoke will always spread.
6. If for some reason you are unable to install it in the
middle of the ceiling, you will also need to install them
at least 10 cm from the wall.
7. If you want to mount them on the wall, install them
10-30.5 cm below the ceiling. figure 1.
8. When your hall is more than 9 meters long, you need
to install multiple detectors.
9. In a sloping roof room, install an alarm that is 0.9
meters from the top. figure 2.
10. How to install a smoke detector in a detachable
house. The mobile house lacks insulation, so you'll
better install the detector 10-30.5 cm from the ceiling.
10CM(4'')
MINIMUM
CEILING
BEST HERE
NEVER HERE
ACCEPTABLE HERE
figure 1.
SIDE WALL
Where not fit to install smoke detector
1. At or near the place where the burning particles
often exist, such as: kitchen, garage (exhaust gas),
stove, water heater or near the oiler.
3. In a humid or humid place; or near a bathroom with
a shower.
4. In a dusty, dirty or greasy place.
5. In very ventilated areas, the smoke will blow away
completely from the unit.
6. In the air recording area, this will block the sensing
chamber.
7. The distance from the fluorescent lamp is less than
305mm. Electrical "noise" can interfere with the sensor.
8. In the "dead air" space, for example, in Figure 1, less
than 10 cm near the corner.
9. The smoke detector is easy to detect in the smoking
room.
ANYWGERE
IN THIS AREA
0.9M(3ft)
0.9M(3ft)
HORIZONTAL DISTANCE
FROM PEAK
figure 2.

Advertisement

loading
Need help?

Need help?

Do you have a question about the LX928-D and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Lexing LX928-D

  • Page 1 Smoke Detector Summary 10CM(4'') MINIMUM LX928-D CEILING The product is a new type of photoelectric smoke detector, When it detects smoke, it will output signal ANYWGERE IN THIS AREA immediately and trigger connected unit to work, which BEST HERE NEVER HERE tell you in advance that fire will occurs and avoid unwanted loss, and take you safety and convenience.
  • Page 2 Customer Service: For all Customer Service and Technical Support enquires please call Monday Smoke to Friday during business hours. detection room Ningbo Lexing Inductor Electronic co.,LTD No.35 Zhuquan Road,Science & Technology Area. Ninghai,Ningbo,Zhingjiang,China Tel:+86-574-65335088 P.C.:315600 E-mail:lexing@lexing.com.cn www.lexing.com.cn www.lexing.com...