Smoke Alarm

Thank you for selecting our product LX-SO-729
LX-SO-729 Smoke Alarm User's Manual
The photoelectric smoke detector is designed to sense smoke that
comes into the detector chamber. It does not sense gas, heat, or
flame. This smoke detector is designed to give early warning of
developing fires by giving off the alarm sounds from its built-in alarm
horn. It can provide precious time for you and your family to escape
before a fire spreads.

SPECIFICATION

Power source: DC9V
Alarm sonority:> 85 db (3m)
Static Current: <10uA
Low Voltage Alarm: 7V+0.5V
Alarm Current: <10mA
Working temperature:-10°C~50°C

WHERE TO INSTALL SMOKE ALARMS

►Install a smoke detector in the hallway outside every separate bedroom area, as shown in Figure 1.
►Install a smoke detector on every floor of a multi-floor home or apartment, as shown in Figure2.
family room
bedroom
smoke detector for minimum security
smoke detector for more security
►Install a smoke detector inside every bedroom.
►Install smoke detectors at both ends of a bedroom hallway if the hallway is more than 40 feet (12 meters) long.
►Install a smoke detector inside every room where one sleeps with the door partly or completely closed, since
smoke could be blocked by the closed door and a hallway alarm may not wake up the sleeper if the door is closed.
►Install basement detectors at the bottom of the basement stairwell.
►Install second-floor detectors at the top of the first-to-second floor stairwell.
►Install additional detectors in your living room, dining room, family room, attic, utility and storage rooms.
►Install smoke detectors as close to the center of the ceiling as possible. If this is not practical, put the detector
on the ceiling, no closer than 20 inches (50 cm) from any wall or corner, as shown in Figure 3.
kitchen
bedroom
bedroom
living room
bedroom
Fiure 1
NO.:LX-SO-729
bedroom
bedroom
bedroom
garage
kitchen
ground
floor
basement
smoke detector for minimum security
Figure 2
www.lexing.com.cn

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the LX-SO-729 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Lexing LX-SO-729

  • Page 1: Smoke Alarm

    Smoke Alarm NO.:LX-SO-729 Thank you for selecting our product LX-SO-729 LX-SO-729 Smoke Alarm User’s Manual The photoelectric smoke detector is designed to sense smoke that comes into the detector chamber. It does not sense gas, heat, or flame. This smoke detector is designed to give early warning of developing fires by giving off the alarm sounds from its built-in alarm horn.
  • Page 2: Where Not To Install Smoke Alarms

    Smoke Alarm NO.:LX-SO-729 ►If some of your rooms have sloped, peaked, or gabled ceilings, try to mount detectors 3 feet (0.9 meter) measured horizontally from the highest point of the ceiling as shown in Figure 4. 50CM(20'') CEILING MINIMUM never here...
  • Page 3 Smoke Alarm NO.:LX-SO-729 INSTALLING YOUR SMOKE DETECTOR The smoke detectors are to be mounted on the ceiling. Please follow these steps to install your smoke detector: 1. Hold the bottom cover firmly and then turn the body anti-clockwise to release the bottom cover down.
  • Page 4 Dry it with lint-free cloth. Do not get any water on the detector components. Replace the battery, and close cover. Test detector to make sure that battery works correctly. NINGBO LEXING INDUCTOR ELECTRONIC CO.,LTD Add:No.35 Zhuquan Road,Science&Technology Area.

Table of Contents