LX608 Smoke Alarm Instruction
Summary
The product is photoelectric smoke alarm, It is only
used in single room in family. For your safety,you'd
better install one alarm in every room. Before using
it, please read the instruction carefully, don't open
the alarm casually avoiding working abnormally.

Attentions for installation:

Before you install the alarm, read the instruction carefully and keep it!!!

Where to install best

1. At first you need install one in the bedroom and route way, because the bedroom is far away from the exit
usually, if you have several bedrooms, you'd better install one alarm in every room.
2. Install it in the stairway, because stairway take an important part in emergent situation。
3. At least install one alarm in every floor.
4. Install one alarm beside the electric appliances in every room.
5. Smoke, heat and burning things will spread horizontally after rising to the ceiling,so install one alarm in the
middle of the ceiling of ordinary structure house. Let the alarm can induce every corner.
6. If alarm can't be installed in the middle of the ceiling for some reasons, the distance the alarm away from
the wall should be more than 10CM.
7. If install alarm on the wall, it should be 10~30.5CM below the ceiling. (Like the diagram 1)
138mm

Specifications

Rated power:DC9V
DC9V / 100-130V/AC
DC9V / 220-240V/AC
Static current: 5uA
Alarm current: 10mA
Alarm level: >85db(3m)
Low voltage alarm: 7V±0.5V
45mm

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the LX608 and is the answer not in the manual?

Questions and answers

Summary of Contents for Lexing LX608

  • Page 1 LX608 Smoke Alarm Instruction 138mm 45mm Summary Specifications Rated power:DC9V The product is photoelectric smoke alarm, It is only DC9V / 100-130V/AC used in single room in family. For your safety,you’d DC9V / 220-240V/AC better install one alarm in every room. Before using Static current: 5uA it, please read the instruction carefully, don’t open...
  • Page 2 8. If the length of the room or the hall is more than 9m, you need install several alarms in the hall. 9. Alarm need be installed 0.9m away from the highest point in room which is gradient. (Like the diagram 2) 10.
  • Page 3 Operate and test 1.Operate: fix the battery in alarm and test it, the alarm is in testing state. when it detects smoke, the alarm will provide the alarm sound more than 85db until it detect no smoke. 2.shine indication: two working ways (1) testing state: flashing once every 30 seconds indicate the operation is normal.
  • Page 4 Use limitation 1.NFPA72 indicate that: the life’s safety lies in noticing the fire in advanced, confirm the right fleeing for life ways. The fire alarm system should make at least half of the people flee from danger, the die are old and sick usually, when dangerous we should more help them.

Table of Contents