Diagnostics - Brant Radiant Heaters DES3 Series Manual

Gas-fired infrared tube heater
Table of Contents

Advertisement

4.0
Operation

Diagnostics

Diagnostics
Lockout:
The controls will automatically lockout the heater system when an external or system fault occurs. There
are two types of lockout:
Soft Lockout: The heater will attempt to light three times. In the event of a failed attempt to light, (gas
pressure, valve, no flame sense etc.), the heater will enter a soft lockout period for 15
minutes and then attempt to light three more times before entering Hard Lockout mode.
Hard Lockout: If proof of flame is not established, a component failure occurs or blockages are evident,
the heater will enter hard lockout. If lockout occurs, the control can be reset by briefly
interrupting the power source.
54
DES3
Series

Advertisement

Table of Contents
loading

Table of Contents