Download Print this page

Exmark PHAZER Setup Instructions page 3

Hide thumbs Also See for PHAZER:

Advertisement

FIGURE 3
4. Align the levers front/rear position. With the
levers in the neutral position, loosen the
hardware and adjust the levers sliding and/or
tilting the lever(s) forward or backward until
properly aligned and tighten hardware (Figure. 4).
FIGURE 4
5. If the ends of the levers hit against each other,
while in the drive position (levers rotated in as far
as possible), make adjustments by moving the
levers outwards to the neutral lock position and
carefully bending them outward. Move them
back to the drive position and check for
clearance. Repeat if necessary.
6. If the machine turns right or left when handles are
pushed forward together, adjust the stop on the
side opposite the direction of turn (see Figure 5).
Move the stop back until the unit drives straight.
Readjust handles if necessary.
FIGURE 5
Installing and Positioning the
Discharge Chute (44" Unit)
1. Remove hardware from deck and install chute
as shown in Figure 6.
2. Lower the discharge chute into position. Tighten
nyloc nuts until chute is snug but can pivot
freely.
FIGURE 6
Servicing the Engine
Refer to Engine Owner's Manual.
Servicing the Hydraulic Oil
The machine is shipped with hydraulic oil. Verify level
on Expansion Tank. (See Figure 7)
1. Start engine and drive the machine forward and
backward for a few minutes to allow any extra
air to purge out of the hydraulic system.
2. Stop engine and wait for all moving parts to
stop. Remove key and engage parking brake.
2. Check expansion tank and if necessary add
MOBIL 1 15W-50 synthetic motor oil to the FULL
COLD line.
3. Replace expansion tank cap and tighten until
snug. Do not overtighten.
109-3910 Rev. B
Page 3 of 4

Advertisement

loading

This manual is also suitable for:

109-3354109-3131