3B Medical RESmart BPAP Quick Reference Sheet

3B Medical RESmart BPAP Quick Reference Sheet

Advertisement

Quick Links

Review Prior Night Summary
Reviewing Sleep Data
The RESmart
allows review of the prior night's sleep data. To access
®
your data, make sure that the blower is not running by pressing the
stop/start button.
Press the Ramp Start button
using the +/- buttons. The data displayed consists of completion
time (Compl), P95 (95th percentile of the airway pressure over
time), AHI (apnea-hypopnea index), and SNI (snore index).
For a discussion on interpreting this data, contact your physician or
home care provider.
Register Your New Account at www.iCodeConnect.com
With iCode Connect you can:
• Easily maintain patient records.
• Generate and archive compliance reports.
• Store patient information, including prescription information for device, mask,
and accessories; model numbers and size information; patient, physician, and
provider contact information; insurance information; reminders; and notes.
• Communicate and share information in real time with other members of your
patient's sleep therapy team.
iCode and iCodeConnect are free of charge with all 3B Medical products.
3B Medical, Inc.
21301 US Highway 27 | Lake Wales, FL 33859 | Phone: (863) 226-6285
Fax: (863) 226-6284 | info@3Bproducts.com | www.3BProducts.com
, and scroll through the display
Quick Reference Sheet
RESmart
BPAP & Auto-BPAP
®
Clinician Set-Up Menu
User
Button (–)
Heated
Humidifier
Button
Pressure Start/Stop
To enter the Clinician's Set-Up Menu:
Remove the power cord from the rear of the RESmart
and hold both the
Start and
reconnecting the power cord.
To Select an Option:
Press the Ramp button once. The cursor will blink, and values may be
changed using the user buttons +/-.
Quickly press and release user buttons.
To Confirm a Setting:
Press the Ramp button again and the cursor will stop blinking
To Advance to the next Option:
Press the User + or - button to move through the Clinician Menu
To SAVE Menu Selections:
Press the Ramp button when the display screen prompts "SAVE"
NOTE: Changes to any options will be final only when you have
confirmed them by pressing the RAMP button when you are at the SAVE
selection on the display screen.
1484_08.2014
Display
Screen
User
Button (+)
Ramp Button
Button
unit. Press
®
Ramp buttons simultaneously, while

Advertisement

loading

Summary of Contents for 3B Medical RESmart BPAP

  • Page 1 To Select an Option: Press the Ramp button once. The cursor will blink, and values may be iCode and iCodeConnect are free of charge with all 3B Medical products. changed using the user buttons +/-. Quickly press and release user buttons.
  • Page 2 Treat P (CPAP Mode only): Indicates CPAP Treatment Pressure. Pressure Range 0.1 S. Default setting is 2.0 S. from 4 to 20 cm H2O in 0.5 cm H2O increment. Ti Min (S and Auto S Mode): Minimum Inspiration Time. It refers to the Init P (CPAP Mode only): The starting pressure if a Ramp time is set.

This manual is also suitable for:

Resmart auto-bpap