  • Page 2: Table Of Contents

    QUICK GUIDE ..............................................WARNINGS COMMON & MODE-BASED SETTINGS ► The LEGEND is a state-of-the-art electronic device. Do not ..............assemble or operate the device before reading the user manual. SEARCH MODES ..................................
  • Page 3: Assembly

    ASSEMBLY (1) After inserting the washers on the lower shaft, place the lower shaft in its location on the search coil. Secure by tightening the screw and nut. Do not overtighten. (2) To join the middle rod with the upper and lower rods, open the lever latches and engage the pieces together.
  • Page 4: Introduction To The Device

    8. Ground Balance Button In The LEGEND, you can ground balance the detector in 3 different ways using this button. For details, please read page 11. 9. Wired Headphones and Charging Input Socket IMPORTANT! If no headphones or charging cable is plugged in the socket, please keep it closed with the screw cap.
  • Page 5: Display

    DISPLAY 1. Info Bar 7. Target ID 2. Clock and Time Tracking 8. Depth Indicator 3. Search Modes 9. User Profile Save & Delete 4. Target ID Scale and Notched Out IDs 10. FerroCheck™ Bar 5. Operating Frequency 11. Pinpoint 6.
  • Page 6: Battery Info

    WATERPROOF REPLACEABLE SPARE BATTERY charger to the wired headphones / charger input socket and the Included in The LEGEND Pro Pack only and sold separately as well, other end to the powerbank. Please note that you will not be able...
  • Page 7: Correct Use

    CORRECT USE Shaft height is wrong Shaft height is correct It is very important to adjust the shaft to your Adjust the height of the shaft so that you are height correctly to be able to search without standing in an upright position, your arm is discomfort and fatigue.
  • Page 8: Quick Guide

    QUICK GUIDE COMMON AND MODE-BASED SETTINGS 1. Assemble the device as per the instructions on page 1. Certain settings are common to all modes; changes in these settings will take effect in all modes. 2. Press the Power & Settings Button to turn on the device. Most of the settings are mode based and they only affect the mode currently selected;...
  • Page 9: Search Modes

    This mode is optimized for use on dry or wet beach sand as well as for underwater use. The LEGEND has 4 search modes designed for different terrains The salt typically present in beach sand and sea causes the sand and targets.
  • Page 10: Sensitivity

    SENSITIVITY TARGET DEPTH Sensitivity is the depth setting of the device. It is also The device provides an estimated target depth according used to eliminate the ambient electromagnetic signals to the signal strength during detection. from the surrounding environment and noise signals Depth Indicator: It shows the target's proximity to the transmitted from ground.
  • Page 11: Frequency

    IDs at depth. In addition, it offers maximum depth for a large range of metals with different sizes on wet salt beach The LEGEND offers Multi frequency, where a wide range sand and underwater by minimizing ground noise.
  • Page 12: Target Id

    Each time the device is turned on, it will start with the C pattern. The LEGEND's Target ID scale consists of 60 lines, each of which represents 1 Target ID. In this pattern, each ID can be rejected or accepted by the user.
  • Page 13 Target ID in the middle will show the ID of the target. 2. To turn off or to turn on the ID press the Pinpoint & Accept/Reject Button. The LEGEND will not generate an audio response for rejected Press targets. However, their IDs will be shown in the discrimination once menu.
  • Page 14: Ground Balance

    GROUND BALANCE The LEGEND is designed to work without ground balancing on most terrains. However, for experienced users and on highly mineralized grounds, ground balancing will bring Press extra depth and stability to the device.
  • Page 15: Pinpoint

    The FerroCheck™ is a unique feature of The LEGEND that you will not pinpoint mode is a non-motion mode. The device continues to give find on other detectors and it provides the user the a signal when the search coil is kept stationary over the target.
  • Page 16: Settings

    False Non-Ferrous Target SETTINGS When targets such as bottle caps -although they generate a non-ferrous Target ID- are checked by the FerroCheck™ feature, To go into the settings menu, press the Power & Settings Button they are identified as alloy which has ferrous (iron) content as once.
  • Page 17: Frequency Shift

    Adjusting the Recovery Speed Frequency Shift can be done in 2 ways in The LEGEND: Manual 1. Press the Power & Settings Button once. Select the Recovery and Automatic.
  • Page 18: Volume

    This control allows you to increase or decrease the device's These advanced tone settings offer various options to volume based on your preference and environmental modify the sounds The LEGEND generates for targets. conditions. The tone setting offers 6 sub settings as follows: Number of Tones , Tone Volume, Tone Frequency, Tone Break, Threshold Level, Volume setting consists of 6 levels and it is set to 3 by default.
  • Page 19 1-Tone For more information, please refer to Tone Frequency setting. The Target ID scale is not divided into any zones, hence there is only 1 tone zone. The LEGEND generates the same tone volume Tone Break and tone frequency for all targets.
  • Page 20 4. Press the plus (+) button to go into the Tone Volume setting. 4.2 Tone Volume 5. The Tone Volume of the selected zone will be displayed on screen. To the left of the ID scale, the selected zone will be displayed This setting allows you to adjust the volume level for each numerically.
  • Page 21 6. Using the right and left buttons, select the zone of which you 4.3 Tone Frequency want to change the Tone Frequency. 7. Once the zone is selected, you can change the Tone Frequency This setting allows you to adjust the Tone Frequency for using the plus (+) and minus (-) buttons.
  • Page 22 4. Press the plus (+) button to go into the setting. 4.4 Tone Break 5. The Tone Break point of the selected zone will be displayed on screen. To the left of the ID scale, the selected zone will be The Tone Break setting allows you to move the point that displayed numerically.
  • Page 23 The Threshold tone will blank to indicate detection of a rejected target. Threshold Tone Blanking Level Rejected Target In Goldfield mode When The LEGEND detects a rejected target the threshold tone continues in the background. Threshold Tone Blanking Level Rejected Target Default Threshold Levels...
  • Page 24: User Profile

    5. User Profile This setting is used to adjust the tone frequency of the The LEGEND offers 4 user profiles where you can save your background hum. It offers a very wide frequency range. settings and create 4 different user profiles.
  • Page 25 16 different sets of settings! Saving a User Profile The LEGEND tracks all changes made in the settings and even if you do not save them in a user profile, the device always starts with the last saved settings when you turn it off and on again.
  • Page 26: Backlight

    6. Backlight 7. Vibration This feature provides feedback to the user by producing a It enables you to adjust the display backlight level accord- vibration effect when a target is detected. ing to your personal preference. It can be used independently or together with the audio response. It ranges from 0 to 5 and A1 to A5 .
  • Page 27: Led Flashlight

    10. Clock It is the headlight used for lighting the area you are The LEGEND has a built in clock that is located in the right scanning while detecting at night or in dark locations. upper corner of the screen.
  • Page 28: Time Tracking

    For land use only, you can also purchase our optional headphones 1 year, 2 months, 20 days and 5 hours. adapter should you want to use The LEGEND with your own wired 3. Press the Power & Settings Button once to go back to the main headphones.
  • Page 29: Technical Specifications

    Bluetooth® word mark and logos are registered trademarks owned by Bluetooth SIG, Inc. Qualcomm® aptX™ is a product of Qualcomm Technologies, Inc. Nokta Makro Detectors reserves the right to change the design, specifications or accessories without notice and without any obligation or liability whatsoever.