Toshiba MMD-AP0056BHP1-E1 Installation Manual page 25

Table of Contents

Advertisement

Check code
Outdoor unit 7-segment display
Wired remote
controller display
L05
L06
L06
No. of indoor units with priority
L07
L08
L08
L09
L10
L10
L17
L20
L26
L26
Number of heat storage units connected
L27
L27
Number of heat storage units connected
L28
L28
L29
L29
Number of IPDU (*1)
L30
L30
Detected indoor unit address
L31
P01
P03
P03
01:Comp. 1 side
P04
P04
02:Comp. 2 side
03:Comp. 3 side
00:
01:Comp. 1 side
P05
P05
02:Comp. 2 side
03:Comp. 3 side
01:Comp. 1 side
P07
P07
02:Comp. 2 side
03:Comp. 3 side
P09
P09
Detected heat storage address
P10
P10
Detected indoor unit address
P12
P13
P13
01:TS condition
P15
P15
02:TD condition
P17
P17
P18
P18
P19
P19
Detected outdoor unit number
P20
P20
0*:IGBT circuit
1*:Position detective circuit error
3*:Motor lock error
4*:Motor current detection
P22
P22
C*:TH sensor error
D*:TH sensor error
E*:Inverter DC voltage error (outdoor unit
fan)
01:Comp. 1 side
P26
P26
02:Comp. 2 side
03:Comp. 3 side
47-EN
AI-NET central
control display
Auxiliary code
96
96
99
99
46
88
46
98
46
46
46
CF
b6
11
1E
21
AF
IC
47
Ob
11
47
AE
bb
E2
O8
22
1A
14
Wireless remote controller
Sensor block display of receiving unit
Operation
Timer
Ready
Flash
SIM
SIM
SIM
SIM
SIM
SIM
SIM
SIM
SIM
SIM
SIM
SIM
SIM
ALT
ALT
ALT
ALT
ALT
ALT
ALT
ALT
ALT
ALT
ALT
ALT
ALT
ALT
ALT
ALT
– 24 –
Check code name
Duplicated indoor units with priority (Displayed in indoor unit with priority)
Duplicated indoor units with priority (Displayed in unit other than indoor unit
with priority)
Group line in individual indoor unit
Indoor unit group/Address unset
Indoor unit capacity unset
Outdoor unit capacity unset
Outdoor unit type mismatch error
Duplicated central control addresses
Too many heat storage units connected
Error in number of heat storage units connected
Too many outdoor units connected
No. of IPDU error
Indoor unit outside interlock
Extended I/C error
Indoor fan motor error
Discharge temp. TD1 error
High-pressure SW system operation
Phase missing detection/Power failure detection
Inverter DC voltage error (comp.)
Inverter DC voltage error (comp.)
Inverter DC voltage error (comp.)
Heat sink overheat error
No heat storage unit water error
Indoor unit overflow error
Indoor unit fan motor error
Outdoor liquid back detection error
Gas leak detection
Discharge temp. TD2 error
Discharge temp. TD3 error
4-way valve inverse error
High-pressure protective operation
Outdoor unit fan IPDU error
Note: Ignore 0 to F displayed in "*" position.
G-TR short protection error
Judging device
I/F
I/F
Indoor unit
Indoor unit, I/F
Indoor unit
I/F
I/F
AI-NET, Indoor unit
I/F
I/F
I/F
I/F
Indoor unit
I/F
Indoor unit
I/F
IPDU
I/F
IPDU, I/F
Heat storage unit
Indoor unit
Indoor unit
I/F
I/F
I/F
I/F
I/F
I/F
EN
IPDU
ID
IPDU
ID
48-EN

Advertisement

Table of Contents
loading

Table of Contents