Tenmars TM-731 User Manual

Tenmars TM-731 User Manual

Temperature/humidity meter

Advertisement

Quick Links

Tenmars
Temperature / Humidity Meter
TM-731
User's Manual
HB2TM7310000
TENMARS ELECTRONICS CO., LTD

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the TM-731 and is the answer not in the manual?

Questions and answers

Summary of Contents for Tenmars TM-731

  • Page 1 Tenmars Temperature / Humidity Meter TM-731 User’s Manual HB2TM7310000 TENMARS ELECTRONICS CO., LTD...
  • Page 3: Table Of Contents

    CONTENTS PREFACE ........................1 CHARACTERISTICS ....................1 SPECIFICATIONS...................... 1 General Specifications ..................1 Electrical Specification: (Temperature: 25°C, Humidity: <90% RH)...... 2 Accuracy: ......................2 OPERATING INSTRUCTIONS................... 3 LCD Display Functions:..................3 Instrument description ..................3 MODE: ......................... 4 MAX/MIN/AVG Button ..................4 Data Hold Button....................
  • Page 4: Preface

    TM-731 PREFACE Thank you for your patronage please read these operating instructions carefully so that you may correctly operate the Temperature / Humidity Meter, allowing it to perform all its intended functions at optimum level. The Temperature /Humidity Meter use a highly accurate sensor chip to measure relative humidity and temperature.
  • Page 5: Electrical Specification: (Temperature: 25°C, Humidity: <90% Rh)

    TM-731 ● Weight : 80g (excluding the battery) ● Accessories : User manual, battery, and carrying case. ● Operating Temperature and Humidity : 0°C ~ +60°C, <95% RH. (non-condensing) ● Storage Temperature and Humidity : -10 to 60°C, <70% RH. (non-condensing) 3.2 Electrical Specification: (Temperature: 25°C,...
  • Page 6: Operating Instructions

    TM-731 OPERATING INSTRUCTIONS 4.4 LCD Display Functions: Low Battery Detect Primary Display Secondary Display Auto-Power Off Indicator Data Hold MAX Data Hold AVG Reading MIN Data Hold Relative Humidity 10. °C Temperature unit 11. DEW-POINT 12. WET-BULB 13. °F Temperture unit 4.5 Instrument description...
  • Page 7: Mode

    TM-731 4.6 MODE:  During normal measurement, press “MODE” button to switch temperatureDew-pointWet-bulb in sequence. 4.7 MAX/MIN/AVG Button The MAX MIN feature reads and updates the display to show the maximum or minimum or AVG value measured after you press the MAX MIN button. Pressing the MAX MIN button for less than 1 second will put the meter into a mode of displaying the maximum, minimum, average readings.
  • Page 8: End Of Life

    TM-731 the ” ” button more than 2 second the LCD “ ” symbol will disappear or enable. End of life Caution This symbol indicates that equipment and its accessories shall be subject to a separate collection and correct disposal.
  • Page 9: Warning And Precautions

    TM-731 Warning and Precautions: ● Please refrain from operating the Temperature / Humidity Meter in an environment with drastic temperature and humidity changes. Do not store the thermometer in an environment prone to high temperature, high humidity, or vigorous vibrations. Avoid exposing the thermometer in a chemical-contaminated environment.
  • Page 10: Accessories

    TM-731 will also respond to unwanted signals that may be present within the measurement circuit. Users should exercise care and take appropriate precautions to avoid misleading results when making measurements in the presence of electronic interference. Accessories: ● User manual.
  • Page 12 Solar power meter, Radiation meter, Clamp meter, Multimeter Phase Rotation tester, Digital Insulation tester Our products of high quality are selling well all over the world TENMARS ELECTRONICS CO., LTD 6F, 586, RUI GUANG ROAD, NEIHU, TAIPEI 114, TAIWAN. E-mail: service@tenmars.com http://www.tenmars.com...

Table of Contents