Download Print this page

AEMC MN379T User Manual page 3

Ac current probe

Advertisement

Common Mode Voltage:
600Vrms
Influence of Adjacent Conductor:
< 15mA/A at 50Hz
Influence of DC on AC signal:
5A Range: DC Current < 1A, < 3%
100A Range: DC Current < 10A, < 10%
Influence of Conductor Position in Jaw:
0.5% of mV output @ 50/60Hz
Influence of Frequency:
5A Range:
40Hz to 1kHz: <0.7% of mV output
1kHz to 3kHz: <2%% of mV output
150A Range:
40Hz to 1kHz: <0.7% of mV output
1kHz to 3kHz: <0.7% of mV output
Influence of Temperature:
≤ 200 ppm/°K, or 0.2% of mV output
per 10°K
Influence of Humidity (10 to 90% RH):
≤ 0.2% of mV output per 10°K @ 18° to 28°C
MECHANICAL SPECIFICATIONS
Operating Temperature:
14° to 131°F (-10° to +55°C)
Storage Temperature:
-40° to 158°F (-40° to +70°C)
Operating Relative Humidity:
10° to 35°C 85% RH
(without roll-off above 35°C)
Maximum Cable Diameter:
One Ø 0.78" (20mm), bus bar 20 x 5 mm
Case Protection:
IP 40 (IEC 529)
Drop Test:
Test per IEC 68-2-32:
1.0 m drop on 38mm of Oak on concrete
Test per IEC 68-2-27
Vibration:
Test per IEC 68-2-6
Dimensions:
5.47 x 2.00 x 1.18"
(139 x 51 x 30mm)
Weight:
180g (6.5oz)
Polycarbonate Material:
Jaws: Polycarbonate with 10% fiberglass
charge, Red UL 94 V0
Case: Polycarbonate 920A Gray
Opening Operations - Life: > 50,000
Output:
10 ft (3m) insulated lead with BNC connector
SAFETY SPECIFICATIONS
Electrical:
Double insulation or reinforced insulation
between the primary or secondary and the
outer case of the handle conforms to IEC
1010-2-32.
Common Mode Voltage:
600V CAT III, Pollution Degree 2
Electromagnetic Compatibility:
Emissivity: EN61326-1 Class B
Electrostatic discharge IEC 1000-4-2
Radiated field IEC 1000-4-3
Fast transients IEC 1000-4-4
Magnetic field at 50/60Hz IEC 1000-4-8
ORDERING INFORMATION
AC Current Probe MN379T .....Cat #2153.02

Advertisement

loading

This manual is also suitable for:

2153.02