DESCRIPTION
The MN379T (Catalog #2153.02) is the latest in compact AC current probes. Designed to meet the most
stringent demands in industry and electrical contracting, it also meets the latest safety and performance
standards. The probe has a measurement range up to 120Arms, a range and resolution capable of
displaying 10mV of output per amp of measured current, a voltmeter accuracy of 0.5% or better to take
full advantage of the accuracy of the probe and an input impedance of ≥ 1MΩ.
WARNING
The safety warnings are provided to ensure the safety of personnel and proper operation of the
instrument. Read the instruction completely.
• Use caution on any circuit: potentially high voltages and currents may be present and may pose
a shock hazard.
• Do not use the probe if damaged. Always connect the current probe to the measuring device
before it is connected around the conductor
• Do not use on non-insulated conductor with a potential to ground greater than 600V CAT III
pollution 2. Use extreme caution when clamping around bare conductors or bus bars.
• Before each use, inspect the probe; look for cracks in housing or output cable insulation.
• Do not use clamp in wet environment or in locations that hazardous gases exist.
• Do not use the probe anywhere beyond the tactile barrier.
INTERNATIONAL ELECTRICAL SYMBOLS
This symbol signifies that the current probe is protected by double or reinforced insulation. Use
only factory specified replacement parts when servicing the instrument.
This symbol signifies CAUTION! and requests that the user refer to the user manual before
using the instrument.
This is a type A current sensor. This symbol signifies that application around and removal
from HAZARDOUS LIVE conductors is permitted.
DEFINITION OF MEASUREMENT CATEGORIES
CAT IV: For measurements performed at the primary electrical supply (<1000V) such as on primary
overcurrent protection devices, ripple control units, or meters.
CAT III: For measurements performed in the building installation at the distribution level such as on
hardwired equipment in fixed installation and circuit breakers.
CAT II: For measurements performed on circuits directly connected to the electrical distribution system.
Examples are measurements on household appliances or portable tools.
RECEIVING YOUR SHIPMENT
Upon receiving your shipment, make sure that the contents are consistent with the packing list. Notify
your distributor of any missing items. If the equipment appears to be damaged, file a claim immediately
with the carrier and notify your distributor at once, giving a detailed description of any damage
99 Washington Street
Melrose, MA 02176
Phone 781-665-1400
Toll Free 1-800-517-8431
Visit us at www.TestEquipmentDepot.com

Advertisement

loading

Summary of Contents for AEMC MN379T

  • Page 1 User Manual DESCRIPTION The MN379T (Catalog #2153.02) is the latest in compact AC current probes. Designed to meet the most stringent demands in industry and electrical contracting, it also meets the latest safety and performance standards. The probe has a measurement range up to 120Arms, a range and resolution capable of displaying 10mV of output per amp of measured current, a voltmeter accuracy of 0.5% or better to take...
  • Page 2 ELECTRICAL SPECIFICATIONS 100A Range - Accuracy 0.1A 100A Nominal Range: 5A, 100A Vs % +0.02mV Measurement Range: 5A: 0.005 to 6A Phase 3.2 ° 2.2° 2.2 ° 2.2 ° 100A: 0.1 to 120A *Reference conditions: 18°C to 28°C, 20 to 75% RH, Transformation Ratio: Voltage output external magnetic field <40 A/m, 48 to 65Hz sine wave, distortion factor less than 1%, no DC component, no...
  • Page 3 Magnetic field at 50/60Hz IEC 1000-4-8 10° to 35°C 85% RH (without roll-off above 35°C) ORDERING INFORMATION Maximum Cable Diameter: AC Current Probe MN379T ..Cat #2153.02 One Ø 0.78" (20mm), bus bar 20 x 5 mm Case Protection: IP 40 (IEC 529) Drop Test: Test per IEC 68-2-32: 1.0 m drop on 38mm of Oak on concrete...
  • Page 4 This warranty is void if the unit has been tampered with, abused ® or if the defect is related to service not performed by AEMC Instruments. Please print the online Warranty Coverage Information for your records.

This manual is also suitable for:

2153.02