Overview
System Description
The heated platen kit is a field installed kit to add heat to
the platen. The additional heat may change the viscosity
properties of the material and allow the material to flow
easier through the system.
The heat is controlled by Graco Control Architecture
components: High Power Temperature Control Modules
(HPTCM) and the display module. The display module
provides the user interface for the entire VPM system.
Power Requirements
A 20A (minimum) - 30A (maximum) circuit breaker must
be installed on the incoming power supply.
Voltage
230 V
400V
*
Add to power requirements of VPM system. Amps
maximum per leg shown.
3A1937C
Wattage
1 Heated Platen
3,500 per Platen
Amps*
2 Heated Platens
17
27
17
34