Setup

For individual screen shot details, refer to VPM Instruc-
tions manual.
1. Make sure the power is on and that the disconnect
switch is in the ON position.
2. Navigate to Conditioning Screen 1 and select the
appropriate heater.
3. Navigate to Conditioning Screen 2 to verify proper
selection of heaters is correct.
4. Press
and navigate to the component you
wish to edit the temperature setpoint and alarm.
5. Press the enter key to display the setpoint and
alarm values associated with that component.
3A1937C
6. Edit the setpoint and alarm values and then press
the page back button to return to the previous
screen.
1. Navigate to the Status Screen, Conditioning Con-
trol Screen.
2. Press
to enter the Conditioning Control
screen.
3. Use the arrows keys to navigate to the desired
zone.
4. Press
to turn the selected zone on. When a
zone is on, the button will be selected. Press the
button again to turn the zone off.
Zone
Setting
Color
Black
OFF
Grey
Yellow
ON
Green
Definition
Dispense Disabled
Dispense Allowed
Dispense Disabled
Dispense Allowed
Setup