Maintenance
Maintenance
Temperature Control Module
Clean
Keep heat sink fins clean at all times. Wipe the fins
clean with a dry cloth or clean them using compressed
air.
NOTE:
Do not use conductive cleaning solvents on the tem-
perature control modules.
Heat Sink Fins
F
. 5: Clean Heat Sink Fins
IG
Install Upgrade Token
NOTE: The Motor Control Module, Fluid Control Mod-
ule, and Temperature Control Module connection to the
system is temporarily disabled during the installation of
upgrade tokens.
To install software upgrades:
1. Use correct software token stated in the table. See
Graco Control Architecture
manual for instructions.
NOTE: Upgrade all modules in the system to the
software version on the token, even if you are
replacing only one or two modules. Different soft-
ware versions may not be compatible.
16
ti12353a1
™
Module Programming
All data in the module (System Settings, USB Logs,
Recipes, Maintenance Counters) may be reset to
factory default settings. Download all settings and
user preferences to a USB before the upgrade, for
ease of restoring them following the upgrade.
See manuals for locations of specific GCA compo-
nents.
The software version history for each system can be
viewed in the technical support section at
www.graco.com.
Token
16G365 VPM:
- High Power Temperature Control Module
F
. 6: Remove Access Cover
IG
Application
ti12354a1