Platen Maintenance
If the platen does not come out of the pail easily when
the pump is being raised, the air assist tube or check
valve may be plugged. A plugged valve prevents air
from reaching the underside of the plate to assist in rais-
ing it from the pail.
1. Turn off main disconnect.
2. Relieve pressure and disassemble air assist valve.
Refer to Supply Systems Repair-Parts manual.
3. Clear air assist tube in platen. Clean all parts of
valve and reassemble. Refer to Supply Systems
Repair-Parts manual.
4. Remove bleed stick from platen. Push bleed stick
through bleed relieve port (T) to remove material
residue. See F
. 7.
IG
5. Remove platen covers. See F
a. Remove platen cover fasteners (70).
b. Remove both platen covers (49) and ground
wire from platen.
6. Remove any excess fluid. Use a soft wire brush on
heater coils (48). See F
7. Inspect platen heater blocks (43) or heater (48) for
burn or melt spots. Replace platen heater if neces-
sary. See F
. 7.
IG
8. Check for loose connections and damaged wires.
9. Follow steps in reverse order to reassemble platen.
NOTE: Torque platen cover fasteners (70) to 60 +/-
10 in-lbs (6.8 +/- 1.1 N•m) for 55 gallon platen.
3A1937C
. 7.
IG
. 7.
IG
Remove and Reinstall Platen Wipers
Refer to Supply Units Repair-Parts manual for instruc-
tions.
Bleed
Stick
T
F
. 7: Remove Platen Covers and Heaters
IG
Maintenance
70
49
43
48
r_wm2179_313296_6a
17