Components
Safety valve
Ignition Switch
Test procedures
1. Refer to page 3-22 for servicing procedure.
2. Measure the resistance after cooling down.
(Multiple meter scale : R x 1)
Upside
Downside
1. Refer to page 3-7 ~ 3-8 for servicing
procedure.
2. Measure the resistance by rotating the cam of
each switch slowly.
(Multiple meter scale : R x 1)
NO
NO
COM
COM
4-4
Normal: Approximately
approximately
40° ~ 80°
40˚
Continuity
80˚
Copyright ©
LG Electronics Inc. All rights reserved.
Only training and service purposes
Results
1 ~ 3 Ω
other
Infinite