Components
Door Switch
(Normally Closed type)
Oven Lamp
Broil or Bake Igniter
Copyright ©
LG Electronics Inc. All rights reserved.
Only training and service purposes
Test procedures
1. Refer to page 3-9 for the servicing procedure
2. Measure the resistance after cooling down
(Multiple meter scale: R x 1)
1. Refer to page 3-13 for the servicing procedure
2. Measure the resistance after cooling down
(Multiple meter scale: R x1)
1. Refer to page 3-10 ~ 3-11 for servicing
procedure.
2. Measure the resistance after cooling down.
(Multiple meter scale : R x 1)
4-3
Results
Door open
Door closed
Continuity
Infinite
Normal: Approximately
30 Ω ± 10%
Normal: 45 Ω ~ 400 Ω
(Room Temperature
Resistance)