Trim Installation - Martin SF42 Series Installation, Operation And Maintenance Manual

42 inch built-in
Table of Contents

Advertisement

T
I
RIM
NSTALLATION
INSTALLATION OF NON-COMBUSTIBLE FACING MATERIALS TO THE FRONT FACE OF THE FIREPL
INSTALLATION OF NON-COMBUSTIBLE FACING MATERIALS TO THE FRONT FACE OF THE FIREPLACE
COMBUSTIBLE FRAMING
MEMBERS FACING MATERIAL
TO TOP OF SPACERS.
F
29
IGURE
INSTALLATION OF COMBUSTIBLE DECORATIVE TRIM AND THE FIREPLACE SURROUND
INSTALLATION OF COMBUSTIBLE DECORATIVE TRIM AND THE FIREPLACE SURROUND
COMBUSTIBLE FRAMING MEMBERS
FACING MATERIAL TO TOP OF SPACERS.
F
30
IGURE
USE ONLY NON-COMBUSTIBLE
MATERIALS BELOW TOP
OF SPACERS.
1" AIR SPACE TO SIDES
AND REAR OF FIREBOX
IT IS RECOMMENDED THAT YOU
INSULATE OUTER AND INNER WALLS
OF CHASE. ALWAYS MAINTAIN THE
OF CHASE. ALWAYS MAINTAIN THE
PROPER CLEARANCE.
F
31
IGURE
COMBUSTIBLE SURROUND
COMBUSTIBLE SURROUND
MATERIALS MAY BE PLACED
MATERIALS MAY BE PLACED
WITHIN SHADED AREAS.
WITHIN SHADED AREAS.
(NOTE: COMBUSTIBLE
(NOTE: COMBUSTIBLE
MATERIALS MUST NOT
MATERIALS MUST NOT
OVERLAP BLACK PAINTED
OVERLAP BLACK PAINTED
SURFACE.)
NON-COMBUSTIBLE
FACING MATERIAL
FIREPLACE FACE
OUTSIDE AIR INLET
SAFETY STRIP
NOTE:
WHEN AN APPROVED ANSI Z21.11.2 UNVENTED ROOM HEATER IS INSTALLED
WHEN AN APPROVED ANSI Z21.11.2 UNVENTED ROOM HEATER IS INSTALLED
IN THIS FIREPLACE, AN H2853 CANOPY MUST ALSO BE INSTALLED.
OUTLINE OF
OUTLINE OF
FIREPLACE
FIREPLACE
FIREBRICK
FIREBRICK
4"
(REF.)
USE ONLY NON-COMBUSTIBLE
MATERIALS BELOW TOP OF SPACERS.
STEEL LINTEL
(OPTIONAL)
CAUTION:
DO NOT COVER
OR RESTRICT SIDE VENT
AREAS WITH SURROUND
OR TRIM MATERIALS.
12" MAXIMUM
COMBUSTIBLE MANTEL
18" MINIMUM FROM FIREPLACE OPENING
TO BOTTTOM OF COMBUSTIBLE MANTEL,
(MANUFACTURER RECOMMENDATION).
SEE NOTE BELOW REGARDING H2853 CANOPY.
SEE NOTE BELOW REGARDING H2853 CANOPY.
1/4"
SCREENED OPENING
SCREENED OPENING
OF FIREPLACE
WARNING:
THE SPACE BETWEEN THE
FACE OF THE FIREPLACE
AND THE NON-COMBUSTIBLE
FACING MATERIAL MUST BE
SEALED. FAILURE TO
PROPERLY SEAL THIS CRACK
CAN CAUSE A POSSIBLE FIRE
HAZARD AND WILL VOID THE
WARRANTY.
TOP EDGE OF FIREPLACE
TOP EDGE OF FIREPLACE OPENING
HEARTH EXTENSION
FRAMING
FRAMING
EXTEND LINE FROM OPPOSITE REAR OF
EXTEND LINE FROM OPPOSITE REAR OF
FIREBOX THRU A POINT 4" IN FRONT OF
FIREBOX THRU A POINT 4" IN FRONT OF
FIREPLACE FACE, AND 1" OUTSIDE OF
FIREPLACE FACE, AND 1" OUTSIDE OF
SCREENED OPENING.
SCREENED OPENING.
FINISHED WALL
FINISHED WALL
53D9022. Rev 1 03/03
27

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Scf42 seriesScf42aSf42aiScf42aiSf42a