Frigidaire FGC6X7XESD Installation Instructions Manual page 6

Gas on glass cooktop 36” with four (4) sealed burners and optional electric built-in oven combination
Hide thumbs Also See for FGC6X7XESD:
Table of Contents

Advertisement

Available languages

Available languages

5. Check for leaks. After connecting cooktop to gas,
check system for leaks with a manometer. If a ma-
nometer is not available, turn the gas supply on to
the cooktop and use a liquid leak detector at all
joints and connections to check for leaks.
Tighten all connections if necessary to prevent gas
leakage in the cooktop or supply line.
Check alignment of valves after connecting the
cooktop to the gas supply to be sure the manifold
pipe has not been moved.
Disconnect this cooktop and its individual
shutoff valve from the gas supply piping system
during any pressure testing of that system at test
pressures greater than 1/2 psig (3.5 kPa or 14"
W.C.).
Isolate the cooktop from the gas supply piping
system by closing its individual manual shutoff valve
during any pressure testing of the gas supply piping
system at test pressures equal to or less than 1/2 psig
(3.5 kPa or 14" W.C.).
CONNECT ELECTRICITY
4
TO GAS COOKTOP
Electrical Requirements:
120-volt, 60 Hertz, properly grounded branch circuit
protected by a 15 amp circuit breaker or time delay fuse.
Do not use an extension cord with this cooktop.
IMPORTANT - (Please read carefully)
FOR PERSONAL SAFETY, THIS APPLIANCE
MUST BE PROPERLY GROUNDED.
The power cord of this appliance is equipped with a
three-prong (grounding) plug which mates with a
standard three-prong grounding wall receptacle (Fig. 1)
to minimize the possibility of electric shock hazard from
this appliance.
The customer should
have the wall receptacle
and circuit checked by a
qualified electrician to
make sure the receptacle
is properly grounded.
Where a standard two-prong wall receptacle is
encountered, it is the personal responsibility and
obligation of the customer to have it replaced with a
properly grounded three-prong wall receptacle.
DO NOT, UNDER ANY CIRCUMSTANCES, CUT
OR REMOVE THE THIRD (GROUND) PRONG
FROM THE POWER CORD.
PREFERRED
METHOD
Insure proper ground
FIGURE 1
exists before use.
CAUTION:
Disconnect electrical supply cord from wall
receptacle before servicing cooktop.
5
INSTALLING BURNER CAPS
BURNER CAP
LOCATING
TABS
ELECTRODE
NOTE: There are no burner adjustments necessary on
this cooktop.
WARNING: Use caution when replacing the burner cap
so the electrode is not damaged.
6
CHECK THE IGNITERS
Operation of electric igniters should be checked after
cooktop and supply line connectors have been carefully
checked for leaks and cooktop has been connected to
electric power.
To operate the surface burner.
1. Push in and turn the surface control to LITE. You will
hear a little ticking noise; this is the sound of the
electric ignitor which lights the burner.
2. After the burner lights, turn to the desired flame size.
The controls do not have to be set at a particular
mark. Use the marks as a guide and adjust the flame
as needed.
ENGLISH – 6
1. Unpack burner
caps and trim rings.
2. Place trim rings
TRIM
over each burner.
RING
3. Make sure the
burner is properly
aligned and leveled.
ORIFICE
Find the recessed
(Do not unscrew)
locating tabs under
each burner cap and
place over the white
electrode in the
burner base as
illustrated.

Advertisement