Download Print this page

Samsung AQ12PGGE Service Manual page 9

Hide thumbs Also See for AQ12PGGE:

Advertisement

Operating Instructions
7. FAN SPEED : Manual (3 step), Auto (4 step)
Fan speed automatically varies depending
on both the difference between setting and
the room temperature.
8. COMPULSORY OPERATION :
For operating the air conditioner without
the remote control.
*The air conditioner starts up in the most
suitable mode for the room temperature:
Room Temperature
Operating Mode
Less than 21˚C
Heat
21˚C or above
Cool
9. SWING : BLADE-H is rotated vertically by
the stepping motor.
*Swing Set : Press the
remote control is displayed on LCD the
and the blades move up and down. If
the one more time press the
blades location is stop.
10. SETTING THE ON/OFF TIMER. :
*ON TIMER : The On Timer enables you
to switch on the air conditioner automati-
cally after a given period of time. You can
set the period of time from 30 minutes to
24 hours.
*OFF TIMER : The Off Timer enables you
to switch off the air conditioner automati-
cally after a given period of time. You can
set the period of time from 30 minutes to
24 hours.
11. GENERATING ANION :
The air conditioner can generate anion
with an ionizer in the indoor unit.
2-4
All manuals and user guides at all-guides.com
12. SELF DIAGNOSIS
Indoor unit room temperature sensor
error (open or short)
Indoor unit heat exchanger temperature
sensor error(open or short)
Indoor FAN MOTOR error :
Keep the RPM value 450 below for 15
seconds
Temperature Setting
22˚C approx.
EEPROM error
24˚C approx.
Error in option
In case of No option set-up
In case of option data error
button under the
13. BUZZER SOUND : Whenever the On/Off
button,
DISPLAY 7-SEGMENT
Error Mode
Operation Off Operation On
OFF
OFF
OFF
OFF
All lamp
blinking
button is pressed or whenever change
occurs to the condition which is set up or
select, the compulsory operation mode,
buzzer is sounded "beep".
Samsung Electronics
Remark
E1
E2
E3
E6
All lamp
blinking

Hide quick links:

Advertisement

loading