Download Print this page

Product Specifications - Samsung AQ12PGGE Service Manual

Hide thumbs Also See for AQ12PGGE:

Advertisement

1. Product Specifications

1-1 Table
Item
Type
Cooling
Heating
Dehumidifying
Cooling
Air volume
Heating
Perfor-
mance
Cooling
Noise
Heating
Cooling
Energy efficiency ratio
Heating
Power
Cooling
Power Consumption
Heating
Cooling
Operating Current
Heating
Cooling
Power
Power factor
Heating
Starting current
Length
Power cord
Number of core wire
Capacity
Outer
Width x Height
Dimension
x Depth
Weight
Liquid
Refrigerant pipe
GAS
Drain hose
Size
Type
Compressor
Motor
Type
Rated output
Type
Blower
Motor
Type
Rated output
Heat exchanger
Refrigerant control unit
Freezer oil capacity
Refrigerant to change(R-22)
Protection device(OLP)
Cooling test Condition
Maximum operation Condition
Samsung Electronics
All manuals and user guides at all-guides.com
Model
Indoor unit
-
|/h
8.0
m
3
/min
8.6
40
dB
40
W/W
V-Hz
W
A
%
A
m
A
mm
890 x 285 x 179
inch
35.0 x 11.2 x 7.0
8.5
kg
mm x L(MT)
mm x L(MT)
D x L(mm)
-
-
Cross-flow
steel
W
15
2ROW 12STEP
CAPILLARY TUBE
cc
g
RAC 12074-9622
INDOOR UNIT : DB27˚C WB19˚C
INDOOR UNIT : DB32˚C WB23˚C
AQ12PGGE
Outdoor unit
Indoor unit
Wall-mounted
12,000BTU/h
13,000BTU/h
1.9
24
8.0
24
8.6
50
40
50
40
2.97
3.25
1-220 / 240-50
1180
1170
5.3
5.1
96.8
99.7
32.0
-
-
250V-10 / 16A
695 x 530 x 280
890 x 285 x 179
27.4 x 20.9 x 11.0
35.0 x 11.2 x 7.0
33.0
8.5
ø6.35 x 5
ø12.7 x 5
ø18 x 2000
Rotary
-
-
-
-
Propeller
Cross-flow
steel
steel
25
15
1ROW 20STEP
2ROW 12STEP
CAPILLARY TUBE
600
820
OUTDOOR UNIT : DB35˚C WB24˚C
OUTDOOR UNIT : DB43˚C WB26˚C
AQ12PBGE
Outdoor unit
Wall-mounted
12,000BTU/h
13,000BTU/h
1.9
24
24
50
50
2.97
3.30
1-220 / 240-50
1180
1150
5.2
6.1
98.7
98.0
32.0
-
-
250V-10 / 16A
740 x 530 x 230
29.1 x 20.9 x 9.1
35.0
ø6.35 x 5
ø12.7 x 5
ø18 x 2000
Rotary
-
-
Propeller
steel
25
2ROW 24STEP
600
910
RAC 12074-9622