2-3 Installation - Thiele Asian Electron PSW1500W Series Instruction Manual

Pure sine wave inverter
Table of Contents

Advertisement

2-2-4 Connect chassis ground terminal to earth or to vehicle chassis using # 8 AWG wire.

2-3 Installation:

Where to install
The power inverter should be installed in a location that meets the following requirements.
2-3-1 Dry – Do not allow water to drip or splash on the inverter.
2-3-2 Cool – Ambient air temperature should be between -20°C and 50°C, the cooler the better.
2-3-3 Safe – Do not install in a battery compartment or other areas where flammable fumes may
exist, such as fuel storage areas or engine compartments.
2-3-4 Ventilated – Allow at least 3 inch of clearance around the inverter for airflow. Ensure the
ventilation openings on the rear and bottom of the unit are not obstructed.
2-3-5 Dust-free – Do not install the inverter in a dusty environments where are dust, wood
particles or other filings/shavings.
These dusts can be pulled into the unit when the cooling fan is operating.
2-3-6 Close to batteries – Avoid excessive cable lengths but do not install the inverter in the
same compartment as batteries.
Use the recommended wire lengths and sizes (see section 2-6).
Also do not mount the inverter where it will be exposed to the gases produced by the
battery. These gases are very corrosive and prolonged exposure that will damage the
inverter.
klick to
klick to
www
www
u-s-v
Y O U R C O N N E C T I O N TO S A F E T Y
ACDC-DCDC
WARNING!
Any damages caused by using incorrect RS232 cable will be
outside of our warranty scope. If you are not sure which one
is correct RS232 cable, please purchase the correct RS232
cable from us directly.
WARNING!
Operation of the inverter without a proper ground, connection
may result in an electrical safety hazard.
WARNING!
Shock Hazard. Before proceeding further, carefully check the
inverter is NOT connected to any batteries, and that all wiring
is disconnected from any electrical sources. Do not connect
the output terminals of the inverter to an incoming AC source.
klick to
www
Y O U R C O N N E C T I O N TO S A F E T Y
Y O U R C O N N E C T I O N TO S A F E T Y
SYSTEME
9
klick to
www
Y O U R C O N N E C T I O N TO S A F E T Y
CONTACT
YOUR CONNECTION TO SAFETY
klick to
www
Y O U R C O N N E C T I O N TO S A F E T Y
CALLBACK

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents