WD388/0/2004
ERROR CODES
Display
Description of fault
E01
Ignition failure - the boiler has attempted to light five times and not succeeded -
check gas supply, air supply, flue, ignitor condition and spark gap.
E02
False flame - the unit is detecting a flame BEFORE ignition. Check gas valve
closure, power supply polarity and voltage and earth connection.
E03
Boiler overheat - check system for blockage, by-pass provision and pump
operation
E05
Fan failure - boiler cannot detect fan rotation. Check fan operation and BOTH
connectors onto fan.
E07
Flue overheat - check combustion and flue temperature vs. return temperature
(Installer numbers 7 and 3 above). The flue temperature should be no more
than 10C above return temperature. Possible heat exchanger fault
E08
Flame circuit error - possible control box fault..
E09
Valve drive error - possible gas valve or control box fault.
E10
Control box errors - possible faulty control box.
E11
The automatic test for calibration of flow and return sensors has failed. Check
both flow and return sensors are located on the correct pipes and are producing
the correct readings.
E12 to E22
Control box errors - possible faulty control box.
E23
Water filling error - check water pressure sensor.
E24
Water pressure lost 4 times in 24 hours - possible leak, check system and boiler.
E25
Control box errors - possible faulty control box.
E26
Flame signal lost 5 times in 4 minutes - The flame is unstable, check
combustion, gas supply, air supply and flue.
E30
Flow sensor short circuit - check connections to flow sensor
E31
Flow sensor open circuit - check connections to flow sensor are in place
E32
DHW sensor short circuit - check connections to DHW sensor
E33
DHW sensor open circuit - check connections to DHW sensor are in place
E34
Mains supply voltage < 180V - Check mains voltage system in dwelling
E35
Mains supply frequency incorrect - Check mains voltage system in dwelling
E37
Water pressure error - check system pressure and pressure sensor
E38
Reset key fault - replace fascia PCB
E40
Water pressure too high - check expansion vessel charge and operation
E41
Communication error between fascia and control box - check cables
E43
Return sensor short circuit - check connections to return sensor
E44
Return sensor open circuit - check connections to return sensor are in place
E45
Flue sensor short circuit - check connections to flue sensor
E46
Flue sensor open circuit - check connections to flue sensor are in place
E99
As E41
Installation & Servicing Instructions
Chapter 6 : Fault Finding
The Keston C36 & C36P Combi Boilers
Page : 30