The VeriPulse IOS solution is designed with you as a dentist and your patient in mind. The scanner is lightweight, small and easy to use, enabling a fast, accurate scanning and great patient experience.
VeriPulse IOS User Manual 1.5 Intended Use The VeriPulse IOS is an optical impression system. It is used to record the topographical characteristics of teeth, dental impressions, or stone models for use in the computer-aided design (CAD) and computer-aided manufacturing (CAM) of dental restorative prosthetic devices.
VeriPulse IOS User Manual 2. What’s in the Box The VeriPulse IOS system includes the following: Name Part Number VeriPulse IOS System (Includes 3 Tips) 70675 USB 3.0 Cable 79278 AC/DC Power Adapter 79279 Save the Box: It is highly recommended that you store the box in a safe place and do not throw it away.
VeriPulse IOS User Manual 3. System Requirements and Specifications 3.1 System Specifications 3.1.1 Scanner Scanner Type Hand-held (chairside) scanner that creates optical impressions for dental restorations Design Compact, lightweight, ergonomic – designed to be operated with little physical effort Dimensions Base...
RTX2000 Series: 2060 or greater - At least 6 GB video memory Quadro RTX3000 and above for laptop - At least 6 GB video memory NOTE: AMD GPU’s are NOT compatible with the VeriPulse IOS. Not meeting minimum hardware requirements will affect the performance of the scanner.
The scanner body consists of the Base and Handpiece, which are connected by a flexible, non-detachable cable. 3.7 Calibration The VeriPulse IOS is factory calibrated. In the case of calibration issues due to transport, please contact your reseller or Whip Mix support technician.
• A 4-5mm (3/16th in) distance between wall and bottom screw head is recommended. CAUTION: If the docking base is not properly installed there is a possibility of the base falling and damaging the scanner. IMPORTANT: Whip Mix is not responsible for accidents or damage caused in the event the scanner falls.
Installing and connecting the VeriPulse IOS Solution To install and connect the VeriPulse IOS Scanner: 1. Place the docking base on a flat, stable surface and place the VeriPulse IOS handpiece securely on the base. 2. Connect the AC/DC power adapter cable to the docking base (the connector socket is located underneath the base).
4.2 Launching WhipMixClinic Once you have connected the VeriPulse IOS, you are ready to launch the WhipMixClinic software installed on your computer. On the computer, click on the WhipMixClinic desktop icon to launch the WhipMixClinic software.
User dossiers can be password protected, and linked to a WhipMixCloud account. 4.2.2 Connecting VeriPulse IOS To WhipMixCloud The VeriPulse IOS Solution enables users to connect to its dedicated cloud platform WhipMixCloud, to easily and efficiently setup and manage file transfers and connections with labs.
VeriPulse IOS User Manual 4.3 Getting Started With WhipMixClinic Using the WhipMixClinic Start Screen When you login to WhipMixClinic, the Patients or Cases default view is displayed (selected in settings). A. Patients/Cases View You can toggle between Patients and Cases views, and Filter or search desired Patients/Cases.
Page 16
Enter Patient details and any useful medical notes. • Click to Create. C. Create new case Click on the Create New Case click bar to directly access the Order Form window in the VeriPulse IOS Scanning module menu. See the VeriPulse IOS Scanning Workflow below.
VeriPulse IOS User Manual 4.4 Configuring WhipMixClinic Settings Settings Menu System settings can be accessed by clicking the System icon located in the top right-hand corner of the WhipMixClinic interface. Settings General Data Sounds Users Upload Order Form To access a specific Settings group, you can select from the left-hand Settings Menu, filter by search or scroll down.
Page 18
An automatic check is done at launch User Manual Click to access User manual online Teamviewer Click to allow secure remote control of your workstation by a Whip Mix support technician Support Page Whip Mix support pag.
Page 19
VeriPulse IOS User Manual Data Settings Data settings enable you to specify Import and Export Database and Export Path settings. You can also choose to share or restrict access to the Database. Description Data Setting Description Click on the EXPORT button to select the...
Page 20
VeriPulse IOS User Manual Import Database Click on the IMPORT button to select the WhipMixClinic Data folder and Import folder. You can import All or Selected Cases. Sound Settings Sound settings enable you to activate/deactivate the Sound Guidance feature during scanning, and to preselect sound effects and volume.
Page 21
VeriPulse IOS User Manual Add And Edit Users Click the right-hand Edit icon to enter/modify User information: email, name and photo. Select Use Password to password protect the User account. Select Use WhipMixCloud to link to a WhipMixCloud account. Upload Settings...
Page 22
VeriPulse IOS User Manual Customizing Restorations Click the Edit button to open the Restoration Editor. The Restoration Editor enables users to select/deselect Restoration types and materials available when filling out Case order forms. Customizing Implants Click the Edit button to open the Implants Editor.
VeriPulse IOS User Manual 5. Using WhipMixClinic 5.1 Managing Patient cases Previewing Patient Cases Select a Patient profile in the left-hand column of the Case Management interface to preview cases already linked to a patient. Edit, Delete or Merge a Patient profile...
WhipMixClinic Direct Scan It is possible to skip the Order Form step and directly access the VeriPulse IOS Scanning module. To do so, select the Start Scanning click bar in the WhipMixClinic Start screen. Note: This feature is not available by default. To activate click Enable Direct Scan Workflow in System Settings.
Page 25
VeriPulse IOS User Manual 3. Enter Order details Order Form details for the patient case are displayed on the right-hand side of the screen. Order Form details Description Patient ID Patient Name or Anonymized ID WhipMixCloud Connection Connection to lab configured in the WhipMixCloud.
Page 26
VeriPulse IOS User Manual 5. Choose Restoration Type • Click on a Restoration Type in the left-hand menu: options available for the selected restoration type are displayed automatically. • Select the Restoration Type: the tooth to which the restoration is applied is highlighted in blue/green.
Page 27
VeriPulse IOS User Manual Example Scan Workflow Menu In the example shown opposite, based on the selected Restorations, the Scan Workflow indicates 6 steps. 1. Pre-Op Scan Used to integrate pre-operative scans in the scan workflow. 2. Maxillary Scan To carry out a scan of the Maxillary arch.
VeriPulse IOS User Manual 5.3 Before You Scan Before scanning, take time to familiarize yourself with the Scanning tools and features available in the VeriPulse IOS solution and the WhipMixClinic interface. 5.3.1 Operating the scanner Start Scan To begin scanning, press the Start/Stop button on the top of the scanner, or click the Start/Stop icon in the right-hand Scanning Tools menu.
5.3.3 The Scanning Live View The Live View window in the lower left displays what the VeriPulse IOS Scanner is actually seeing. 3D reconstruction of the scan is displayed in the middle of the screen. If the scanner loses connection...
2D IMAGES button. 5.3.4 Recommended Scan Workflow Before launching a scan, make sure the VeriPulse IOS Scanner is correctly connected to the computer via the USB 3.0 cable and the WhipMixClinic software is running. Make sure the computer on which the WhipMixClinic software is installed is connected to an external power source.
VeriPulse IOS User Manual Begin your scan by starting on the arch of chosen restoration. If you have selected to scan the antagonist, you may start by scanning either arch. 5.4.1 Scanning the Maxillary Arch To make the scanning process more comfortable...
Page 32
VeriPulse IOS User Manual 2. Scan the Maxillary Buccal area Scan the BUCCAL area from molar to center line on LEFT side, ensuring the connection of surfaces: • Scan with 45°angle to get part occlusal + part buccal • Scan with 90°angle to get last part of buccal ii.
VeriPulse IOS User Manual Processing Data When the scan is complete: i. Turn the scanner off using the Start/Stop button on the handle of the scanner. The VeriPulse software will process the Maxillary scan data before moving on to the next phase of the Scan Workflow.
5.4.5 Bite Alignment The VeriPULSE IOS enables you to carry out Automatic Bite Alignment based on the previously scanned Maxillary and Mandibular arches. Note: When you select Bite Alignment, allow a few seconds for the arch scans to load.
Page 35
Based on the left and right-side bite scans, the VeriPULSE IOS will automatically reconstruct the alignment of the full Maxillary and Mandibular arches in occlusal mode.
Page 36
B. Align Maxillary-Paired Points Note: The VeriPulse IOS software calculates the matching position based recognizable surrounding surfaces and not on the specific point you have chosen, so you do not need to worry about replicating the exact position.
15. Carry out the same procedure as described above in steps 1-13. 5.4.6 Auto-Realignment Once you have carried out the Bite Alignment in the VeriPulse IOS Scan Workflow, you can use the Auto-Realignment feature to optimize the scans. Click on the Auto-Realignment icon in the Scanning Tools menu.
VeriPulse IOS User Manual 5.4.7 Using Bite Alignment Tools When you have successfully completed the Bite Alignment for your patient, you can use the Bite-Alignment tools to visually inspect the quality of the alignment scans. The Bite-Alignment Tool menu is displayed below the 3D reconstructed image of the bite alignment.
Page 39
VeriPulse IOS User Manual WhipMixClinic Case Information & Settings Settings Description Patient Patient ID Lab connection configured in WhipMixCloud and requested delivery date (via interactive lab calendar). Restorations Restorations specified in Case Setup (Order Form). Notes/Attachments Relevant patient dossier details and documents.
VeriPulse IOS User Manual SEND TO LAB: WhipMixCloud Case View When the lab clicks on the email notification of your order, it will open the relevant Case details in WhipMixCloud. This provides the lab you have configured a connection to and to which you have sent an order via WhipMixCloud with secure access to all Patient Case files associated with the Order.
VeriPulse IOS User Manual The WhipMixCloud Login window will open automatically, inviting you to Login or to Create a New Account. 4. Click Create New Account: in the dialog box Fill in the required fields (marked with a red *) and click Create.
VeriPulse IOS User Manual 4. Click Send. A request email is sent to the lab inviting it to accept the connection. 5. Click Connections to view connection status or to add another lab connection. The status of your Connection Request is displayed: (Accepted/Waiting for approval)
VeriPulse IOS User Manual WhipMixCloud will provide the lab you have configured a connection to, and to which you have sent the order from WhipMixClinic, with secure access to all Patient Case files associated with the Order 6.4 Configuring WhipMixCloud Settings System WhipMixCloud settings can be configured for your WhipMixCloud User account.
VeriPulse IOS User Manual Configuring View & Notification Settings To configure View & Notification settings for your WhipMixCloud account: 3. Click Settings in the scroll menu. The following View and Notification options are available: WhipMixCloud View & Push Description Notification Settings Show ‘Cases/Drafts’...
VeriPulse IOS User Manual 2. Under the Users section in Settings, edit the current user and check “yes” for use Evident Hub. 3. Login to Evident Hub using the email address for your Evident account. 7. Maintenance 7.1 Cleaning the Handpiece...
Step 5: Ensure the dry cycle is complete prior to removing the tip from the autoclave. If the pouch is damp with moisture, proper sterilization cannot be guaranteed.7.3 Disposal The VeriPulse IOS is an electrical device with electronical components inside and should be disposed of in accordance with local environmental laws and regulations.
The VeriPulse IOS is an electrical device with electronic components inside and should be disposed of in accordance with local environmental laws and regulations. 7.4 Calibration The VeriPulse IOS is calibrated in the factory and therefore does not require calibration when installed. WARNING: General prohibition indication. The functionality of the system can be destroyed in the case of incorrect use.
If unauthorized changes have been made to delivered system and accessories, the warranty by Whip Mix Corporation becomes void. Whip Mix Corporation will not accept any responsibility or liability for the improper functioning of the product in such a case.
VeriPulse IOS User Manual 8.3.2 Approved Software The VeriPulse IOS device is designed to operate with the WhipMixClinic software. See section 5 below for details. WARNING: The VeriPulse IOS scanner should only be used with validated, compatible software. 8.3.3 Equipment Failure WARNING: In case of system malfunction or failure, you should: Prevent any contact between the system and the patient.
VeriPulse IOS User Manual 8.5 Electrical Safety 8.5.1 Electrical Shock WARNING: There is a risk of electrical shock when opening or attempting to open any part of the system; only qualified service personal should open parts of the system. 8.5.2 Stress on Cables...
If this use is necessary, it is advisable that this and the other equipment be observed to verify that they are operating normally. VeriPulse IOS Performance: Under normal use, the VeriPulse IOS should be transmit images to the laptop/notebook with the installed image manipulation software and User Manual the video stream is visible in the bottom left corner of the screen.
Page 52
VeriPulse IOS User Manual VeriPulse IOS is intended for use in a professional healthcare setting with electromagnetic environment specified below. Electromagnetic Emissions Emissions Test Compliance Electromagnetic Environment Guidance RF Emissions CISPR 11 Group 1, Class A VeriPulse IOS uses RF energy only for its internal function.
Page 53
Portable and mobile RF IEC 61000-4-3 60601-1-2 2014 60601-1-2 2014 communications equipment should be used no closer to any part of the VeriPulse IOS system, including cables, than the recommended separation distance calculated Conducted RF 3V 0.15-80MHz 3V 0.15-80MHz from the equation applicable to...
Page 54
VeriPulse IOS User Manual Recommended Separation Distances Between Portable and Mobile RF Communications Equipment and the VeriPulse IOS System that is not Life-Supporting Rated maximum Separation distance according to fequency of transmitter m output power of 150 kHz to 80 MHz 80 MHz to 800 MHz 800 MHz to 2.5 GHz...
VeriPulse IOS User Manual 8.10 Symbols on the VeriPulse IOS and Transport Case Symbol Description Manufacturer’s trade name and address (ISO 15223-1) Date of manufacture (ISO 15223-1) Equipment Power On/Off (push/push) USB plug Warning, Consult Accompanying Documents General mandatory action manual...
If you are experiencing issues with your software, please check the list of common issues provided below prior to contacting the Whip Mix technical support team. It could be simply a question of a minor issue that can be fixed quickly. However, if you’re still experiencing problems after following the recommendations in this section, then please contact the Whip Mix technical support team.
VeriPulse IOS User Manual Please keep the shipping container for future use. Products returned to Whip Mix for repair should be properly packaged. To obtain warranty service, follow the procedure described in the Repair Service section. Failure to do so will cause delays and additional expense to the customer.
Page 58
Distributed by: Whip Mix Corporation 361 Farmington Avenue Louisville, KY USA 40209 whipmix.com For technical support, please contact us via productsupport@whipmix.com or phone number 800-626-5651, extension 1437, For additional material and user information go to https://www.whipmix.com/veripulse 3D Imaging & Simulation Corp. Americas 365 Herndon Pkwy., #18...
Need help?
Do you have a question about the VeriPulse IOS and is the answer not in the manual?
Questions and answers