8-4. AUTO RESTART FUNCTION
When the indoor unit is controlled with the remote controller, the operation mode, the set temperature, and the fan speed
are memorized by the indoor electronic control P.C. board. "AUTO RESTART FUNCTION" automatically starts operation
in the same mode just before the shutoff of the main power.
Operation
If the main power has been cut, the operation settings remain.
After the power is restored, the unit restarts automatically according to the memory.
(However, it takes at least 3 minutes for the compressor to start running.)
How to disable "AUTO RESTART FUNCTION"
Turn off the main power for the unit.
Cut the jumper wire to JR77 on the indoor electronic control P.C. board. (Refer to 10-7.)
NOTE:
The operation settings are memorized when 10 seconds have passed after the indoor unit was operated with the remote
controller.
If main power is turned OFF or a power failure occurs while AUTO START/STOP timer is active, the timer setting is can-
celled.
If the unit has been turned OFF with the remote controller before power failure, the auto restart function does not work as
the power button of the remote controller is OFF.
To prevent the breaker from tripping OFF due to the rush of starting current, systematize other home appliance not to
turn ON at the same time.
When some air conditioners are connected to the same supply system, if they are operated before power failure, the
starting current of all the compressors may flow simultaneously at restart.
Therefore, the special counter-measures are required to prevent the main voltage-drop or the rush of the starting current
by adding to the system that allows the units to start one by one.
8-5. Wi-Fi INTERFACE SETTING UP
This Wi-Fi interface communicates the status information and controls
the commands from the MELCloud by connecting to an indoor unit.
Wi-Fi interface
Wi-Fi interface introduction
No.
Item
1
MODE switch
It selects modes.
2
RESET switch
It resets the system and ALL settings.
3
ERR LED (Orange)
It shows the network error state.
NET LED (Green)
It shows the network state.
5
MODE LED (Orange)
It shows the Access point mode state.
6
UNIT LED (Green)
It shows the indoor unit state.
(1) MODE switch
(2) RESET switch
the factory default.
NOTE:
information will be lost. Take great care in implementing this operation.
OBH766B
INDOOR electronic control
P.C. board
Wi-Fi interface
Description
ERR
NET
MODE
UNIT
RESET
MODE
JR77
(1) Open the front panel and remove the Wi-Fi interface.
(2) Set up a connection between the Wi-Fi interface and the router.
Refer to the SETUP MANUAL and SETUP QUICK
REFERENCE GUIDE provided with the unit.
For SETUP MANUAL, please go to the website below.
http://www.melcloud.com/Support
(3) Put the Wi-Fi interface back and close the front panel
after the setup is completed.
http://www.melcloud.com/Support
NOTE:
Ensure that the Router supports the WPA2-AES encryption setting before
starting the Wi-Fi interface setup.
The End user should read and accept the terms and conditions of the Wi-Fi
service before using this Wi-Fi interface.
To complete connection of this Wi-Fi interface to the Wi-Fi service, the Rout-
er may be required.
This Wi-Fi interface will not commence transmission of any operational data
from the system until the End user registers and accepts the terms and con-
ditions of the Wi-Fi service.
This Wi-Fi interface should not be installed and connected to any Mitsubishi
Electric system which is to provide application critical cooling or heating.
At the time of relocation or disposal, reset the Wi-Fi interface to the factory
default.
Mitsubishi Electric's Wi-Fi interface is designed for communication to Mit-
subishi Electric's MELCloud Wi-Fi service.
Third party Wi-Fi interfaces cannot be connected to MELCloud.
Mitsubishi Electric is not responsible for any (i) under performance of a sys-
tem or any product; (ii) system or product fault; or (iii) loss or damage to any
system or product; which is caused by or arises from connection to and/or use
of any third party Wi-Fi interface or any third party Wi-Fi service with Mitsubishi
Electric equipment.
For the latest information regarding MELCloud from Mitsubishi Electric
Corporation, please visit www.MELCloud.com.
11