Size of the cutout in the panel:
68 x 68mm (2.68in) +0.7 -0mm
Find Quality Products Online at:
Intended Use: The APM has been specifically designed for engineers
requiring an effective way to monitor and display data. The APM
accepts a range of electrical inputs (depending on the model) and
displays the data on its integrated multi-format display. The APM has
been designed for installation into electrical cabinets or display
panels. Output models include two independent outputs that can be
configured by the user to be either digital set-point outputs or 4-20mA
monitor outputs.
Use the DIP switches to set the Temperature Meter bar graph range
and annunciators to standard values. Use the software application to
configure custom settings.
The switch positions are shown in the table where:
0 = OFF and 1 = ON.
Thermocouple Types
Size
GlobalTestSupply
www.
Intended Use
Operating Specification
Operating Specification
B, C, E, J, K, N, R, S, T
0.25% plus Thermocouple Accuracy
Accuracy
The DIP switches are
on the back of the unit.
.com
sales@GlobalTestSupply.com

Advertisement

loading
Need help?

Need help?

Do you have a question about the APM and is the answer not in the manual?

Questions and answers

Summary of Contents for Trumeter APM

  • Page 1 Intended Use Intended Use: The APM has been specifically designed for engineers requiring an effective way to monitor and display data. The APM Temperature accepts a range of electrical inputs (depending on the model) and displays the data on its integrated multi-format display. The APM has...
  • Page 2 DIP Switches Wiring Diagrams DIP switch settings:- Thermocouple Input Switch Display Scale Thermocouple Type Units DC supply ONLY 1234 AC supply must not 0000 Custom have COM link 1000 1820 ºC Fuse 0100 -200 1000 ºC 1000 1100 -210 1200 ºC 1200 0010...
  • Page 3 Safety Warnings WARNING: INSTALLATION AND MAINTENANCE MUST BE CARRIED OUT BY SUITABLY QUALIFIED AND COMPETENT PERSONEL ONLY. HAZARDOUS VOLTAGES MAY BE PRESENT ON THE CONNECTION TERMINALS. INSTALLATION Install this product in accordance with local regulations, codes • and instructions. All fuses must be 0.5A / 250V Type F with a breaking capacity •...
  • Page 4 Specification VALUE Environment –10 to +60 deg C Temperature - operating –40 to +70 deg C Temperature - storage 2000 metres Altitude 0 – 85 % Relative Humidity (non-condensing) - Continuous 0 – 95 % Relative Humidity (non-condensing) - Intermittent Pollution Degree (IEC664) IP65 IP rating (from the front)

This manual is also suitable for:

Apm-temp-apoApm-temp-apsApm-temp-ansApm-temp-ano