Table of Contents Preface Safety Instructions and Warnings Use according to the intended purpose Mounting in a control panel Electrical Installation Description Display/Operating elements Inputs INP A, INP B RESET GATE LOCK INPUT Outputs Output 1 Output 2 Active Outputs Programming Entering the programming Choice of main menus...
Mounting in a control panel Preface Mount the device away from heat Please read this instruction manual sources and avoid direct contact carefully before installation and start-up. with corrosive liquids, hot steam or Please observe all warnings and similar. CAUTION advice, both for your own safety and for general plant safety.
Description T1-6 Decade key T1 … T6 6-digit multifunction LCD display Prog/Mode key Easy-to-read 2-line LCD-display with annunciators R Reset key for both the displayed preset and the status of the two outputs Current count value / main counter Simultaneous display of the actual value and of the Preset value/ Total count/ Batch counter presets or auxiliary counters Versions with/without backlit display...
Outputs Entering a sub-menu The sub-menu is opened with the Output 1 Prog/Mode key and the first menu item is displayed. Relay with potential-free make (NO) contact or optocoupler with open emitter and collector Selecting the menu items Output 2 The Prog/Mode key is used to Relay with potential-free make (NO) contact or select a menu item within the...
Pressing the Prog/Mode key 7.8.2 Table: Parameter Sets acknowledges this prompt and P.SEt 1 P.SEt 2 P.SET 3 terminates the programming; the modified settings are saved in Func Count Count Count the EEPROM. InP.PoL The text SAVE is FiLtEr displayed for 2 s Count Cnt.dir uP.dn...
7.8.4 Pulse Counter Quadrature x4 INP A: count input 0° INP B: count input 90° 7.8.4.1 Submenu for the Signal and Each pulse edge of INP A and Control inputs INP B will be counted. Menu for programming the signal Ratio measurement [A / B] and control inputs Inp A: count input A...
Page 8
Count mode SUBTRACT Count mode ADDING with Output 1 active when automatic reset and Total count status < preset value 1 counter Output 2 active when Output 2 (timed signal) active count status < 0 when main counter = preset Reset to preset 2 value 2 Automatic reset to zero when...
7.8.4.3 Submenu for configuration Manual reset (with red key) and electrical reset (reset input) Submenu for matching the input pulses and display No reset possible (red key and reset input inhibited) Multiplication factor Only electrical reset possible Multiplication factor can be (reset input) programmed from 00.0001 to 99.9999.
Page 10
Simple frequency 7.8.5.2 Submenu for configuration measurement Submenu for matching the input Inp A: Frequency input pulses and display Inp B: no function Differential measurement [A – B] Multiplication factor Inp A: Frequency input A Multiplication factor can be Inp B: Frequency input B programmed from 00.0001 to Total measurement [A + B] 99.9999.
Lower line Inp A and Inp B: no function Display colour The timer is reset by means of a Upper line RESET (to zero when adding, to Lower line green valid edge, before zero is to be valid edge, before zero is to be Start: 1.
Page 12
Lock input main counter = preset value 2 Batch counter counts the number When the Lock input is activated of automatic repetitions of preset the programming is inhibited. Output 1 active when batch counter > preset 1 manual reset sets both counters When the Lock input is activated to zero the setting of the preset values is...
Page 13
Tracking preset mode Display colour (for 6.92x.x1x3.xx0] Display colour When preset 2 is changed then upper line preset 1 automatically tracks it. lower line Reset to zero Preset 1 relative to preset 2 (see Display colour also section 17. Output upper line operations) lower line...
Page 14
SUB mode output operations: 7.8.6.6 Submenu for Preset 2 permanent signal at Output 1, Submenu for Preset 2 becomes passive when count < Preset 1 ADD mode output operations: timed signal at Output 1, ADD mode output operations: becomes active when count > permanent signal at Output 2, Preset 1.
Preset 2 and subsequently with negative direction and when count < Preset 2 SUB mode output operations: timed signal at Output 2, becomes passive with negative 7.9.2 Setting with Teach-In Function direction and when count < zero Program the MPI input to tEAch and subsequently with positive direction and when count >...
10.4 Timer or NPN optocoupler Switching capacity 30 V DC/10 mA Seconds 0.001 s ... 999 999 s for IC = 10 mA: max. 2.0 V CESAT Minutes 0.001 min ... 999 999 min for IC = 5 mA: max. 0.4 V CESAT Hours 0.001 h ..
13 Frequencies (typical) 13.2 Frequency meter HTL level 13.1 Pulse counter AC supply typ. Low 2,5 V HTL level typ. High 22 V AC supply typ. Low 2,5 V DC supply 12V typ. Low typ. High 22 V typ. High 10 V DC supply 12V typ.
14 Input modes: Pulse counting Function Diagram PNP: Count on rising edge NPN: Count on falling edge Note: No counting when GATE input is active P = Preset Cnt.Dir Inp A: Count input Inp B: Count direction Add: Display 0 --> Preset Sub: Display Preset ->...
Page 21
Function Diagram PNP: Count on rising edge NPN: Count on falling edge Note: No counting when GATE input is active Quad 4 A 90° B Inp A: Count input Count on rising and on falling edges Inp B: Count input Count on rising and on falling edges, Reverse direction...
16 Input modes: Frequency meter Function Diagram PNP: Count on rising edge NPN: Count on falling edge Inp A: Frequency input Inp B: no function AsubB Inp A: Frequency input 1 Inp B: Frequency input 2 Formula: A - B AaddB Inp A: Frequency input 1 Inp B: Frequency input 2...