Electronic preset counter with two presets (26 pages)
Summary of Contents for Trumeter APM
Page 1
Intended Use: The APM has been specifically designed for engineers requiring an effective way to monitor and display data. The APM accepts a range of electrical inputs (depending on the model) and displays the data on its integrated multi-format display. The APM has been designed for industrial use only, by installation into electrical cabinets or display panels.
Wiring Diagrams MODBUS CONNECTIONS MODBUS AND OUTPUTS CURRENT MEASUREMENT VOLT AGE MEASUREMENT DIGITAL OUTPUT CONNECTIONS MODBUS AND OUTPUTS CURRENT MEASUREMENT VOLTAGE MEASUREMENT 1.800.561.8187 information@itm.com www. .com...
Page 3
Wiring Diagrams ANALOG OUTPUT CONNECTIONS 4-20mA +88.8 MODBUS AND OUTPUTS CURRENT MEASUREMENT VOLTAGE MEASUREMENT SINGLE PHASE POWER METER CONNECTIONS - LINE POWER MODBUS AND OUTPUTS CURRENT MEASUREMENT VOLTAGE MEASUREMENT NOTE: DO NOT CONNECT CT SECONDARYS TO EARTH. CT’S EARTHED THROUGH N TERMINAL 1.800.561.8187 information@itm.com www.
Page 4
Wiring Diagrams SINGLE PHASE POWER METER CONNECTIONS - LOCAL POWER FUSE MODBUS AND OUTPUTS CURRENT MEASUREMENT VOLTAGE MEASUREMENT NOTE: DO NOT CONNECT CT SECONDARYS TO EARTH. CT’S EARTHED THROUGH N TERMINAL SPLIT PHASE POWER METER CONNECTIONS - LINE POWER MODBUS AND OUTPUTS CURRENT MEASUREMENT VOLT AGE MEASUREMENT NOTE: DO NOT CONNECT CT SECONDARYS TO EARTH.
Page 5
Wiring Diagrams SPLIT PHASE POWER METER CONNECTIONS - LOCAL POWER FUSE MODBUS AND OUTPUTS CURRENT MEASUREMENT VOLTAGE MEASUREMENT NOTE: DO NOT CONNECT CT SECONDARYS TO EARTH. CT’S EARTHED THROUGH N TERMINAL THREE PHASE AND NEUTRAL POWER METER CONNECTIONS - LINE POWER MODBUS AND OUTPUTS CURRENT MEASUREMENT VOLTAGE MEASUREMENT...
Page 6
Wiring Diagrams THREE PHASE (NO NEUTRAL) POWER METER CONNECTIONS - LOCAL POWER FUSE MODBUS AND OUTPUTS CURRENT MEASUREMENT VOLTAGE MEASUREMENT EARTH NOTE: DO NOT CONNECT CT SECONDARYS TO EARTH. CT’S EARTHED THROUGH N TERMINAL THREE PHASE POWER METER CONNECTIONS with PT AND CT - LOCAL POWER FUSE MODBUS AND OUTPUTS...
Safety Warnings WARNING: INSTALLATION AND MAINTENANCE MUST BE CARRIED OUT BY SUITABLY QUALIFIED AND COMPETENT PERSONEL ONLY. HAZARDOUS VOLTAGES MAY BE PRESENT ON THE CONNECTION TERMINALS. INSTALLATION • Install this product in accordance with local regulations, codes and instructions. • An external fuse must be fitted in-line with the PSU. Recommended fuse: 0.5A/300V with a breaking capacity of 35A or greater.
Control Outputs Isolation Modbus Current Control Input Inputs Analog Output Voltage Input Power Supply Isolation barriers: Galvanic Isolation Barrier Size Size of the cutout in the panel: 68 x 68mm (2.68in) +0.7 -0mm Front Panel Buttons Change Parameter: Auto Scroll Parameters: Press to automatically switch Press to move between parameters parameters every 3 seconds...