9. Make sure that all detergent residue
is removed from the upper and lower
part of the recess. Use a small brush
to clean the recess.
10. Reassembly the drawer as follows:
a. Place the handle if was
disassembled.
b. Place the bottom cover and
press till "click" sound.
c. Place the top cover on the tanks
compartment and press till "click"
sound.
d. Replace components on manual
compartment.
11. Insert the detergent dispenser into
the guide rails and gently close it till
"click" sound. Run the rinsing
program without any clothes in the
drum.
To restore the functionality,
refill tanks with detergent
and softener. If you place a
wrong additives in the tanks,
you can easily recover it by
using the drain plug on both
side of the drawer. Before
opening drain plugs ensure
to place below the drawer a
basin or suitable containers
to collect the liquid. Ensure
to properly close the plugs
before refilling.
14.9 Cleaning the drain pump
WARNING!
Disconnect the mains plug
from the mains socket.
Regularly check the drain
pump filter and make sure
that it is clean.
Clean the drain pump if:
• The appliance does not drain the
water.
• The drum does not turn.
• The appliance makes an unusual
noise because of the blockage of the
drain pump.
• The display shows the alarm code
.
WARNING!
• Do not remove the filter
while the appliance
operates.
• Do not clean the pump if
the water in the appliance
is hot. Wait until the water
cools down