primatech Q550A Operating Instructions Manual

Pneumatic flooring tool

Advertisement

PNEUMATIC TOOL Q550A
The pneumatic nailer Q550A is a professional tool
specially developed for the installation of 3/8" to 3/4" solid
and engineered hardwood flooring. It is designed for easy
maintenance where major components can be accessed
within seconds without the need of any tool.
The Q550A tool is offered in 2 different configurations:
• standard L-type 18
nails
GA
• combo nailer/stapler taking standard L-type 18
or ¼" crown 18
staples
GA
SAFETY MEASURES
These important guidelines should always be followed to
work safely with the Primatech pneumatic tool Q550A:
• Read these instructions thoroughly before using this tool
and keep it handy for reference if necessary.
• Always keep hands, feet or other body parts away from
the fastener ejection area.
• Never aim the tool in any direction other than the
working area.
• Always carry or manipulate the tool by its handle while
the air supply hose is connected.
• Never hit the head cap of the actuator if the plastic base
is not sitting perfectly on the working surface.
• Never leave the tool laying down on its side while the air
supply hose is connected; the tool should always be left
on the floor, standing on its plastic base.
• Do not alter or remove safety.
• Always disconnect the air supply hose when the tool is
not in use or when move to another work area.
• Never service or repair the tool, clear obstructions or
make adjustments while the air supply hose is
connected.
• Only compressed air should be used to power this tool;
do not exceed 110 psi (7.6 bar).
• Never use oxygen or any other compressed gas as a
power source for this tool. Explosion may occur.
• Always wear OSHA-required Z-87 safety glasses with
side shields.
PNEUMATIC FLOORING TOOL
OPERATING INSTRUCTIONS
Complete documentation specific to your tool can be
retrieved by scanning the QR-Code applied on the tool.
You will find updated information such as Operation
Manual, Part list, Schematic specifics and Technical
Notes specific to your tool as it was manufactured; as well
as useful information for ordering replacement parts.
Technical support, information &
schematics at
http://ts.primatech.ca/550
nails
GA
• Always wear proper ear and foot protection while the air
supply hose is connected.
• Always remove fasteners from the magazine before
servicing tool.
Do not remove or alter safety. Do not use a tool
with a defective safety. Never depress the
safety contact with your hands when tool is
connected to air supply. Extreme caution is
advised when using this tool.
Eye protection is recommended and should
be worn by the operator and other in working
area. Accidental ejection of fasteners or wood
debris could cause severe eye injury.
In some environments, ear protection might
be required, as working condition may include
exposure to high noise levels which lead to
hearing damage.
Wearing safety boots and safety hat is also
highly recommended.
Note: All the personal protection equipments
must meet national standards.
Q550A

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Q550A and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for primatech Q550A

  • Page 1 Notes specific to your tool as it was manufactured; as well within seconds without the need of any tool. as useful information for ordering replacement parts. The Q550A tool is offered in 2 different configurations: Technical support, information & schematics at •...
  • Page 2 ADJUSTING FOR HARDWOOD THICKNESS ADJUSTING ROLLER BASE The Q550A pneumatic tool is fitted with a fully adjustable The Q550A can be mounted on a roller base (standard on plastic base designed to prevent contact with the top edge Q550AR). of the flooring. It is important to adjust the tool to fit the flooring prior any installation.
  • Page 3: Loading The Tool

    Never not use a compressed air pressure higher than 100 psi (7.0 bar). PREVENTIVE MAINTENANCE This tool requires minimal lubrication. Use only detergent-free oil such as Primatech P-090. Few drops of oil weekly in the air inlet is sufficient. Other types of lubricant may degrade the seals.
  • Page 4: Operation

    It should offer some resistance, but if it moves Damage may result from such abuse. Contact your too easily, it may be required to replace the piston wear- Primatech distributor for more information. ring. When opening the tool for maintenance, always clean all components of dirt, grit, or particles.
  • Page 5 ASSEMBLING THE TOOL This section describes how to re-assemble the tool after maintenance. The following procedure assumes that the gate/foot assembly along with the resting block are already installed. [1] Insert the seal bushing in the lower section of main body and engage it onto the upper portion of the gate/foot assembly.
  • Page 6 INSTALLING THE SAFETY You shouldn't need to remove the safety stop mechanism unless the element Q-061 do not swivel or has a broken tip. • Assemble together parts Q-061, Q-061A , Q-061C and Q-061D. • Insert the short end of Q-061B as shown. •...
  • Page 7: Troubleshooting

    • Use fewer tools simultaneously; do not exceed the capacity of the compressor or of the delivery system. Primatech ‘s sole liability hereunder will be to replace any • Drain water from the compressor. part or accessory which proves to be defective within the specific time period.

Table of Contents