primatech Q900A Operating Instructions Manual

Pneumatic flooring tool

Advertisement

PNEUMATIC TOOL Q900A
The pneumatic
nailer Q900A is a professional
EDGE
tool specially developed for the installation of 1/2" to
3/4" solid hardwood flooring. It is designed to blind nail
within 2" of vertical obstructions such as end walls,
stairways, cabinets, railings, and more.
The Q900A features the
PRIMPACT
easy maintenance where major components can be
accessed within seconds without the need of any tool.
The Q900A tool also features a cam operated height
adjuster.
The Q900A uses specialty 1¾"
standard 18
flooring nails.
GA
SAFETY MEASURES
These important guidelines should always be followed
to work safely with the Primatech pneumatic tool
Q900A:
• Read these instructions thoroughly before using this
tool and keep it handy for reference if necessary.
• Always keep hands, feet or other body parts away
from the fastener ejection area.
• Never aim the tool in any direction other than the
working area.
• Always carry or manipulate the tool by its handle
while the air supply hose is connected.
• Never hit the head cap of the actuator if the plastic
base is not sitting perfectly on the working surface.
• Never leave the tool laying down on its side while the
air supply hose is connected; the tool should always
be left on the floor, standing on its plastic base.
• Always disconnect the air supply hose when the tool
is not in use or when move to another work area.
• Never service or repair the tool, clear obstructions or
make adjustments while the air supply hose is
connected.
• Only compressed air should be used to power this
tool; do not exceed 110 psi (7.6 bar).
PNEUMATIC FLOORING TOOL

OPERATING INSTRUCTIONS

Complete documentation specific to your tool can be
retrieved by scanning the QR-Code applied on the tool.
You will find updated information such as Operation
Manual, Part list, Schematic specifics and Technical
Notes specific to your tool as it was manufactured; as
well as useful information for ordering replacement
parts.
striking module for
Technical support, information &
schematics at
nails. Do not use
EDGE
• Never use oxygen or any other compressed gas as a
• Always wear OSHA-required Z-87 safety glasses with
• Always wear proper ear and foot protection while the
• Always remove fasteners from the magazine before
Eye protection is recommended and should
be worn by the operator and other in
working
fasteners or wood debris could cause
severe eye injury.
In some environments, ear protection might
be required, as working condition may
include exposure to high noise levels which
lead to hearing damage.
Wearing safety boots and safety hat is also
highly recommended.
Note:
equipments must meet national standards.
Printed in Canada
Q900A
http://ts.primatech.ca/900
power source for this tool. Explosion may occur.
side shields.
air supply hose is connected.
servicing tool.
area.
Accidental
All
the
personal
ejection
of
protection
v143 07/18

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Q900A and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for primatech Q900A

  • Page 1: Operating Instructions

    Technical support, information & accessed within seconds without the need of any tool. schematics at http://ts.primatech.ca/900 The Q900A tool also features a cam operated height adjuster. The Q900A uses specialty 1¾" nails. Do not use EDGE standard 18 flooring nails.
  • Page 2 ADJUSTING FOR HARDWOOD THICKNESS CONNECTION & AIR SUPPLY The Q900A pneumatic tool is fitted with a cam This tool requires clean & dry air. The use of a filter and operated height adjustment base. a pressure regulator is recommended. Adjusting the base for flooring thickness: Use a detachable male coupler with 3/8"...
  • Page 3: Loading The Tool

    LOADING THE TOOL OPERATION The pneumatic nailer Q900A uses specialty 1¾" Unload the tool and rest it onto the subflooring, EDGE nails. Do not use standard 18 flooring nails. Connect the hose and cycle tool once or twice without EDGE fastener.
  • Page 4: Maintenance And Repair

    [1] Loosen up the head lock and rotate it ¼ turn to methods. Maintenance should only be performed by disengage it from the head. trained personnel. Use only genuine Primatech replacement parts. [2] It is usually not necessary to remove the head cap.
  • Page 5 ASSEMBLING THE TOOL This section describes how to re-assemble the tool after maintenance. The following procedure assumes that the gate/foot assembly along with the resting block are already installed. [1] Insert the seal bushing in the lower section of main body and engage it onto the upper portion of the gate/foot assembly.
  • Page 6: Troubleshooting

    HECK FOR AIR LEAKS or replacement of part or tool is required, the complete tool or part(s) must be returned to Primatech or at such At rest, this tool should not have any air leaks. Before authorized warranty service point of Primatech,...

Table of Contents