Getting started

Each action is executed with a programmed heating set point for
a programmed time (steps of 12 hours).
A maximum of 20 different actions can be programmed.
The program is activated in the test run operation.
When the program is stopped by an error or an operation switch
off or a power failure, the U3 error code will be displayed.
To resolve the error codes, see
Procedure
Example of program:
H
(2)
(1)
[F-07]=48 h
[F-07]=24 h
(1)
(2)
[F-06]=25°C
[F-06]=35°C
H Heating set point
t Time
(1) Action number 1
(2) Action number 2
1
Set field settings
■ The different actions are programmed as follows:
(refer to
"8.9. Field settings" on page 26
change the field settings)
1 Set in [F-05] (Action number), the action to be programmed,
example 1.
Save the new value by pressing the pr button.
2 Set in [F-06] (Heating set point of selected action number
[F-05]), example 25°C.
Save the new value by pressing the pr button.
3 Set in [F-07] (Time of selected action number [F-05]),
example 24 hours.
Save the new value by pressing the pr button.
4 Repeat step 1 through 3 to program all the actions.
INFORMATION
The not set actions will not be programmed
because these actions has time [F-07] equal to 0
hours as default.
So in case to many actions are programmed and
the quantity needs to be reduced, set the time
[F-07] to 0 hours of the actions that does not
need to be executed.
■ Consult the different actions to confirm good setting values
as follows:
(Refer to
"8.9. Field settings" on page 26
change the field settings)
1 Set in [F-05] (Action number), the action to be consulted,
example 1.
Save the new value by pressing the pr button.
2 Consult [F-06] (Heating set point of selected number [F-05])
3 Consult [F-07] (Time of selected number [F-05]), example 24
hours.
4 Repeat step 1 through 3 to consult all the actions.
■ Enable the "underfloor heating screed dry-out program" as
follows:
1 Set in [F-08] (Underfloor heating screed dry-out program
enabled/disabled) to 1 (enabled).
2 When finished, press the z button to exit the FIELD SET
MODE.
EKHBH/X016BB
Indoor unit for air to water heat pump system
4PW62572-1A – 01.2011
"11.3. Error codes" on page
48.
t
to know how to
to know how to
2
Activate
INFORMATION
The activation of the "Underfloor heating screed
dry-out program" is similar to the starting the Test run
operation
1 Push the z button 4 times so the t icon will be
displayed.
2 To start the "Underfloor heating dry-out program" press the
y button.
3 The "Underfloor heating dry-out program" will start and
display the action and temperature setting of action
number 1. The icon e is also displayed.
3
During activation
The underfloor heating dry-out program will automatically run
trough all programmed actions.
4
End
1 When all actions are executed, the program will automatically
be stopped by switching off the unit and the t icon will be
disappeared.
2 When the (Underfloor heating dry-out program) has ended
successfully the [F-09] will have value 21.
INFORMATION
When the program is stopped by an error, by an
operation switch off or by a power failure, then the U3
error will be displayed.
To resolve the error codes, see
page
48.
In this case [F-09] (Latest action number executed)
will contain the latest action executed.
[F-08] The "Underfloor heating screed dry-out
program enabled (1)/disabled (0)" is always set to 0
(disable) when a program has been started once. This
means that in case a second time an underfloor
heating screed dry-out program must be started then
[F-08] needs to be set again.