1
Product Specific and Important Safety Information
A. Appliance Certification
GG18NV/PV, GG24NV/PV, GG18NIF/PIF
MODEL:
GG24NIF/PIF
LABORATORY: CSA
TYPE: Unvented Room Heater
STANDARD: ANSI Z21.11.2-2016 (Unvented Heaters)
ANSI Z21.60-2017∙CSA 2.26-2017 (Decorative
Gas Appliances for Installation in Solid-Fuel
Burning Fireplaces)
This product is listed to ANSI standards for "Unvented
Room Heaters" and applicable sections of "Gas Burning
Heating Appliances for Manufactured Homes" and "Gas
Fired Appliances for Use at High Altitude."
NOTICE: This installation must conform with local codes.
In the absence of local codes you must comply with the
National Fuel Gas Code, ANSI Z223.1-latest edition in
the U.S.A.
NOT INTENDED FOR USE AS A PRIMARY HEAT SOURCE.
This appliance is tested and approved as either supplemen-
tal room heater or as a decorative appliance. It should not
be factored as primary heat in residential heating calcula-
tions.
B. BTU Specifications
Models
GG18NV
(0-2000 FT)
GG18PV
(0-2000 FT)
GG24NV
(0-2000 FT)
GG24PV
(0-2000 FT)
GG18NIF
(0-2000 FT)
GG18PIF
(0-2000 FT)
GG24NIF
(0-2000 FT)
GG24PIF
(0-2000 FT)
4
Maximum
Minimum
Front
Input
Input
Orifice
BTU/h
BTU/h
29,000
21,000
#51
29,000
22,500
#60
37,000
27,000
1.8mm
37,000
29,000
#57
29,000
21,000
#51
29,000
22,500
#60
37,000
27,000
1.8mm
37,000
29,000
#57
Monessen • Glow Getter Owner's /Installation Manual • 4621-900 Rev. E • 09/20
NOTE: For LP models an external regulator is required
to reduce supply pressure to a maximum of 13" w.c.
C. Gas Pressures
Inlet Minimum
Inlet Maximum
Gas Valve Manifold
Pressure Setting
Pilot Regulator
NATURAL GAS: An external regulator is required to reduce
supply pressure to a maximum of 10
systems operating at higher pressure.
PROPANE/LPG: An external regulator is required to reduce
supply pressure to a maximum of 13" w.c.
Pilot/ODS
The gas log heater is fitted with a specially designed safety
pilot (ODS assembly) which senses the amount of oxygen
available in the room and shuts the gas log heater off if the
oxygen level begins to drop below a satisfactory level. The
pilot can only be relit when adequate fresh air is available.
D. High Altitude Installations
NOTICE: If the heating value of the gas has been reduced,
Rear Orifice
these rules do not apply. Check with your local gas utility
or authorities having jurisdiction.
#46
When installing above 2000 feet elevation: Reduce input
1.35mm
rate 4% for each 1000 feet above sea level.
Check with your local gas utility to determine proper
2.5mm
orifice size.
#53
E. Non-Combustible Materials Specification
#46
Material which will not ignite and burn. Such materials are
1.35mm
those consisting entirely of steel, iron, brick, tile, concrete,
slate, glass or plasters, or any combination thereof.
2.5mm
Materials that are reported as passing ASTM E 136,
#53
Standard Test Method for Behavior of Materials in
a Vertical Tube Furnace at 750 ºC shall be considered
non-combustible materials.
NATURAL
PROPANE (LP)
5.0" w.c.
11.0" w.c.
10.5" w.c.
13.0" w.c.
3.5" w.c.
10" w.c.
3.5" w.c.
" w.c. on natural gas