Note: Have the gas supply line installed in accordance with
local codes, if any. If not, follow ANSI Z223.1. Installation
should be done by a qualified installer approved and/or
licensed as required by the locality. (In the Commonwealth
of Massachusetts installation must be performed by a
licensed plumber or gas fitter).
D. Gas Service Access
Depending upon local code, a manual gas shutoff, in
a readily accessible area may be required and located
upstream from the appliance.
WARNING
Fire Risk.
Explosion Hazard.
High pressure will damage valve.
• Disconnect gas supply piping BEFORE
pressure testing gas line at test pressures
above 1/2 psig.
• Close the manual shutoff valve BEFORE
pressure testing gas line at test pressures
equal to or less than 1/2 psig.
E. Check Gas Pressure
Millivolt
The valve regulator controls the burner pressure which
should be checked at the pressure test point.
Turn captured screw counter clockwise two or three turns
and then place tubing to pressure gauge over test point
(use test point "OUT" closest to control knob). After taking
pressure reading, be sure and turn captured screw clock-
wise firmly to re-seal. Do no over torque. Check for gas
leaks. See Figure 4.2.
Test Port "OUT"
Figure 4.2 - Pressure Test Point Location Millivolt Control
FP2266
valve
16
Monessen • Glow Getter Owner's /Installation Manual • 4621-900 Rev. E • 09/20
Intellifire™ Plus ODS (IFP)
Check the gas pressure with the appliance burning and
the control set to HIGH.
The valve regulator controls the burner pressure which
should be checked at the pressure test point.
Turn captured screw counterclockwise two or three turns
and then place tubing to pressure gauge over test point.
Use test point "A" closest to gas inlet. After taking pres-
sure reading, be sure and turn captured screw clockwise
firmly to reseal. Do not over torque. Check for gas leaks.
See Figure 4.3.
Figure 4.3 Pressure Test Point Location