Getting Started; Product Features And Specifications - Monessen Hearth EYF18-R Installation And Operating Instructions Manual

Unvented gas log heater or vented decorative appliance
Table of Contents

Advertisement

GETTING STARTED - FEATURES and SPECIFICATIONS
Gloves are recommended when
handling ceramic fiber logs to prevent
skin irritation from loose fibers.
Logs are fragile - handle with care.
MAKE SURE YOU HAVE RECEIVED ALL
PARTS:
Check your packing list to verify that all listed parts have
been received. You should have the following:
Unvented gas log burner assembly
Plastic bag containing crushed volcanic rock
Installation/operating instructions
Two (2) anchoring screws
Grate
The millivolt controlled version of this heater is the only
style designed to be operated with optional devices for
ON/OFF functions. The following options may be used
with the millivolt controlled heater. These options are not
packaged with the log set.
Hand held Remote with receiver
Wall thermostat with 15' wire
Wall switch with 15' wire
Hand held Thermostat Remote with receiver
Carefully inspect the contents for shipping damage. If any
parts are missing or damaged, immediately inform the
dealer from whom you purchased the appliance. Do not
attempt to install any part of the appliance unless you
have all parts in good condition.
WHAT YOU WILL NEED FOR INSTALLA-
TION:
You must have the following items available before pro-
ceeding with installation:
External regulator (for propane/LPG and 1/2 lb.
natural gas systems only)
Piping which complies with local codes
Screwdriver
Drill with 5/32 bit
Manual shutoff valve
Pipe sealant approved for use with propane/LPG
(Resistant to sulfur compounds)
Pipe wrench or appropriate size crescent wrench
set
Tee joint.
Sediment trap
Monessen • EYF18/24 Gas Log Heater Installation/Owner's Manual • 65D1009 • Rev G • 01/2020
EYF Series Unvented Gas Log Set
GAS PRESSURES
Control
Fuel
Regulator Pressure
Nat.
Pilot Regulator
Nat.
Max. Inlet Pressure
Nat.
Min. Inlet Pressure
Nat.
Regulator Pressure
LP
Max. Inlet Pressure
LP
Min. Inlet Pressure
LP
*NOTE: An external regulator is required to reduce supply pres-
sure to a maximum of 13" w.c.
GAS SPECIFICATIONS
Model
Fuel Control
EYF18NM
Nat. Manual
EYF18NV
Nat. Millivolt
EYF18PM
LP
Manual
EYF18PV
LP
Millivolt
EYF24NM
Nat. Manual
EYF24NV
Nat. Millivolt
EYF24PM
LP
Manual
EYF24PV
LP
Millivolt
IGNITION CONTROLS
Piezo ignitor allows ignition of the pilot without the use of
matches or batteries.
Manual control has three (3) positions:
OFF - All gas to the gas logs is shut off at the valve.
IGN - Valve position to light/maintain a standing pilot.
HI/LOW - Variable position corresponding to desired
flame height (heat input)
Millivolt control has four (4) positions:
OFF - All gas to the gas logs is shut off at the valve.
IGN - Valve position to light/maintain a standing pilot.
ON - Valve position to turn ON/OFF log set with remote
switch/thermostat.
HI/LOW - Variable position to control flame height (heat
output).
PILOT
The gas log heater is fitted with a specially designed safety
pilot light (ODS assembly) which senses the amount of
oxygen available in the room and shuts the gas log heater
off if the oxygen level begins to drop below a satisfactory
level. The pilot can only be relit when adequate fresh air
is available.
THERMAL GENERATOR
The millivolt gas log pilot is fitted with a millivolt generator
to provide power for remote activation.
Manual
Millivolt
4.0" w.c.
3.5" w.c.
n/a
3.5" w.c.
10.5" w.c.
10.5" w.c.
5.0" w.c.
5" w.c.
10.0" w.c.
10.0" w.c.
13.0" w.c.
13.0" w.c.
11.0" w.c.
11.0" w.c.
Gas Rate
Max.Input Min. Input
BTU/h
BTU/h
30,000
18,000
30,000
26,000
30,000
22,500
30,000
24,500
36,000
19,000
36,000
24,000
36,000
25,000
36,000
29,000
5

Advertisement

Table of Contents
loading

Table of Contents