Millivolt Control Lighting Instructions - Monessen Hearth EYF18-R Installation And Operating Instructions Manual

Unvented gas log heater or vented decorative appliance
Table of Contents

Advertisement

EYF Series Unvented Gas Log Set

MILLIVOLT CONTROL LIGHTING INSTRUCTIONS

1. STOP! Read the safety information label.
2. Make sure the manual shutoff valve is fully open.
3. This gas log set is equipped with an ignition device (piezo) which automatically lights the pilot. If piezo
ignitor does not light the pilot, refer to instructions for Match Lighting Instructions, Page 23.
4. Turn gas control knob clockwise
switch to OFF position.
5. Wait (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas,
STOP! Follow What to Do if You Smell Gas, Page 20. If you don't smell gas, go to next step.
6. From OFF position, turn the gas control knob counterclockwise
knob for 5 seconds.
7. With the control knob pushed in, push in and release the piezo ignitor button to light the pilot.
8. Continue pushing the control knob in for a further 60 seconds to prevent the flame detector from shut-
ting off the gas while the probe is warming up. Release the control knob.
9. Turn gas control knob counterclockwise
10. After the pilot has been lit for one minute, the burners can be turned on. Turn the ON/OFF switch to
ON position or adjust thermostat to desired setting.
11. If the gas logs will not operate, follow the instructions To Turn Off Gas To Heater below and call your
service technician or gas supplier.
FP2275
Figure 36 -
Pilot
1. Turn control knob clockwise
2. If applicable: Turn ON/OFF switch to OFF position and/or set thermostat (if present) to lowest setting.
3. If applicable: Turn off all electric power to the heater.
22
Monessen • EYF18/24 Gas Log Heater Installation/Owner's Manual • 65D1009 • Rev G • 01/2020
to the OFF position, set thermostat to lowest setting and turn ON/OFF
TO TURN OFF GAS TO HEATER
to OFF position to completely shut off the heater.
OPERATING INSTRUCTIONS
to the ON position.
Piezo
ON/OFF Switch
Hi/Lo Control
On/Off/Pilot Control
Figure 37 -
Millivolt Controls
FP2542
millivolt controls
to IGN position. Push in control
FP2542

Advertisement

Table of Contents
loading

Table of Contents