SUN2000-(75KTL, 100KTL, 110KTL, 125KTL) Series
User Manual
Mounting Structure Requirements
Figure 4-1 Mounting structure
Installation Angle Requirements
The solar inverter can be support-mounted or wall-mounted. The installation
angle requirements are as follows:
Issue 11 (2021-11-10)
You are advised to install the inverter in a sheltered place or install an awning
over it.
The inverter will be corroded in salt areas. Before installing the inverter
outdoors in salt areas, consult Huawei. A salt area refers to the region within
500 meters from the coast or prone to sea breeze. The regions prone to sea
breeze vary with weather conditions (such as typhoons and monsoons) or
terrains (such as dams and hills).
NO TE
The SUN2000-125KTL-M0 should be physically separated from third-party wireless
communication facilities and residential environments by distance greater than 30 m.
The mounting structure where the solar inverter is installed must be fire
resistant. Do not install the solar inverter on flammable building materials.
Ensure that the installation surface is solid enough to bear the solar inverter.
In residential areas, do not install the solar inverter on drywalls or walls made
of similar materials with a weak sound insulation performance because the
noise generated by the solar inverter may interfere with residents.
Install the solar inverter vertically or at a maximum back tilt of 75 degrees to
facilitate heat dissipation.
Do not install the solar inverter at forward tilted, excessive back tilted, side
tilted, horizontal, or upside down positions.