1.
Pressing the Start button cycles to the next test function.
Number of times
the Start
button is pressed
None
Check the version and code of ma-
chine.
1 time
Gas Coin type : P1:Og
Gas Card type : P1:Cg
Gas OPL type : P1:Pg
2 time
PDA CHECK
3 time
Motor runs.
GAS TYPE: Motor runs.
4 time
GAS TYPE: GAS valve runs.
5 time
Motor+Valve
LED & KEY CHECK
Press High Temp. button.
6 time
Press Med Temp. button.
Press Low Temp. button.
Press No Heat button.
7 time
Test ends.
Door switch
During check, if the
(Motor & Heater Off, Buzzer beeps
door is open.
seven times)
During check, if the
Test goes back at step 3.
door is closed
(Motor on & Heater Off )
NOTE
Do not use
.
Checking point
PROGRAMMING MODE
Display
LqC 1
Version and code of machine (All LED on)
Display 88:88 and P1:XX and gU:XX and gd:XX alter-
nately.
XX is product type or the version number.
Ir--
Measured moisture value (70~239)
Current temperature (5~70)
(Displays the temperature inside the drum in ° Celsius.)
Current temperature (5~70)
(Displays the temperature inside the drum in ° Celsius.)
Version and code of machine
LqC1
dE
(The door is open. Please close the door completely)
Measured moisture value (70~239)